1041 Power Shelf Rear Panel
115 VAC
2.0 A
60 HZ
ALARM
CONTACTS
+
GND NC C NO
AB
F1
FUSE RATING
3.0 A 125 V
12345678
F2
FUSE RATING
.25 A 125 V
48 VDC
2A
1
1 8 RETURN
8 -48 VDC
Rear Panel Description
1
AC Power Cord:
This cord can be connected to any available 110 V outlet.
2
Fuse F1:
Fuses A and B protect the main power feeds.
3
48 VDC:
The three screw terminals on the left are used to connect a -48 VDC load to the main feeds.
4
Alarm Contacts:
The three isolated contacts on the right permit connection to a remote indicating device. The contacts may be
configured as normally closed (NC) or normally open (NO). NO and NC refer to the contact’s relationship to the common (C)
contact under a ‘no alarms’ condition.
5
Fuse F2:
Fuses 1 through 8 protect the multiple load terminal strip with a rating of 0.25 A each.
6
-48 VDC:
These 8 screw terminals are used to connect multiple 0.25 A loads to the main feeds.
7
Return:
These 8 screw terminals are used as returns for the multiple feeds.
2 4 5 6
Simplified Schematic
P/S A
P/S B
-48 V
-48 V
F1-A
3 A
F1-B
3 A
F2
1
F2
2
F2
3
F2
4
F2
5
F2
6
F2
7
F2
8
21 345678
21 345678
RETURN
-48 VDC
+
–
••
31 7
GND
8 fuses at 0.25 A each
TxPORT Customer Service
127 Jetplex Circle
Madison, Alabama 35758
Customer Service Returns:
800-926-0085, ext. 227
Product Technical Sup-
port:
(8 – 5 Central Time)
800-285-2755 or
205-772-3770
Emergency After Hours:
800-285-2755
E-Mail (Internet Address):
support@txport.com