Verilink AS4000 (34-00244) Product Manual Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Počítačový hardware Verilink AS4000 (34-00244) Product Manual. Verilink AS4000 (34-00244) Product Manual User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 210
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - User Manual

Verilink AS4000User ManualJune 2000P/N 880-503457-001-C

Strany 2 - FCC Requirements

x Verilink AS4000 User ManualOctal DS-1/E1 Utilities... 9-20About Menu...

Strany 3 - CAUTION:

Quad DS-1 Module5-12 Verilink AS4000 User ManualAbout MenuThe About Menu provides access to information about the Quad DS-1 module firmware and hardw

Strany 4

Verilink AS4000 User Manual 6-1Chapter6Quad Port Sync Data ModuleThe AS4000 module which is labelled Quad Port Sync Data on its front panel presents m

Strany 5 - Safety Precautions

Quad Port Sync Data Module6-2 Verilink AS4000 User ManualConfiguration MenuFrom the Quad Port Sync Data module Main Menu, select Configuration to setu

Strany 6 - Customer Service

Quad Port Sync Data ModuleVerilink AS4000 User Manual 6-3More About TimingThe following applies to the Quad DS-1 Sync Data module as well as synchrono

Strany 7 - Table of Contents

Quad Port Sync Data Module6-4 Verilink AS4000 User Manualtransmit clock signal back towards the Quad Port Sync Data module on the optional third pair

Strany 8

Quad Port Sync Data ModuleVerilink AS4000 User Manual 6-5Diagnostics MenuThe Diagnostics Menu supports loopbacks and test patterns for two purposes:•

Strany 9 - Verilink AS4000 User Manual

Quad Port Sync Data Module6-6 Verilink AS4000 User ManualMore AboutLoopbacksLocal Loop and Remote Loop on the Quad Port Sync Data module are both bi-d

Strany 10 - Interfaces and Cables B-1

Quad Port Sync Data ModuleVerilink AS4000 User Manual 6-7Utilities MenuThe Utilities Menu is used to place the module in and out of service, reset the

Strany 11 - Overview

Quad Port Sync Data Module6-8 Verilink AS4000 User ManualFigure 6-8 Monitor System Manager Clock Display Use this menu only at the direction of Verili

Strany 12 - AS4000 Concept

Quad Port Sync Data ModuleVerilink AS4000 User Manual 6-9Table 6-3 System Manager InterfaceConfiguration Map sequence numberA number used to identify

Strany 13 - Features

Verilink AS4000 User Manual 1-1Chapter1OverviewScopeThis manual describes the Verilink AS4000 Integrated Access System. The content of this manual is

Strany 14 - Management

Quad Port Sync Data Module6-10 Verilink AS4000 User ManualAbout MenuThe About Menu, illustrated in Figure 6-10, gives revision information about the Q

Strany 15 - System Components

Verilink AS4000 User Manual 7-1Chapter7DS-3 ModuleThe AS4000 module which is labelled DS-3 Module on its front panel presents console menus in which i

Strany 16

DS-3 Module7-2 Verilink AS4000 User ManualFigure 7-1 Configuration Menu DS-3 Configuration MenuIn addition to its single T3 network interface, the DS-

Strany 17 - Power Supplies

DS-3 ModuleVerilink AS4000 User Manual 7-3Figure 7-2 T1 Configuration Manager Menu Table 7-1 T1 Configuration Manager Menu VVVVeeeerilinrilinrilinrili

Strany 18 - Specifications

DS-3 Module7-4 Verilink AS4000 User ManualFigure 7-3 T1 Channel Configuration Menu T1 ChannelConfigurationMenuMost of the fields shown in Figure 7-3 a

Strany 19 - AS4011 AS4004

DS-3 ModuleVerilink AS4000 User Manual 7-5T3 Port Configuration MenuTo access the T3 Port Configuration Menu, from the Main Menu:• Select Node Summary

Strany 20

DS-3 Module7-6 Verilink AS4000 User ManualReceive Loop Timing If Enabled, the DS-3 module uses the clock frequency it recovers fron the receive circui

Strany 21 - Quick Set-Up Guide

DS-3 ModuleVerilink AS4000 User Manual 7-7Options MenuTo access the DS-3 Module Options Menu, from the Main Menu:• Select Node Summary• Select T3• Sel

Strany 22 - Work Flow

DS-3 Module7-8 Verilink AS4000 User ManualDiagnostics MenuTo access the DS-3 Diagnostics Menu, from the Main Menu:• Select Node Summary• Select the de

Strany 23 - Figure 2-2 Example Work Flow

DS-3 ModuleVerilink AS4000 User Manual 7-9Line Diagnostics CenterFrom the Line Diagnostics Center, several submenus may be invoked to perform addition

Strany 24 - Step-by-Step

Overview1-2 Verilink AS4000 User ManualPurpose and UseThe Access System 4000 (AS4000) is an integrated access device that provides multiple access int

Strany 25 - Configure System

DS-3 Module7-10 Verilink AS4000 User ManualFigure 7-8 T3/LIU Loop Select Screen T3 Loopbacks IllustratedThe T3 local loopback faces the local AS4000 s

Strany 26

DS-3 ModuleVerilink AS4000 User Manual 7-11Figure 7-10 DS-3 Module T1 LoopbacksUtilities MenuFrom the Main Menu:• Select Node Summary,• Select T3,• an

Strany 27

DS-3 Module7-12 Verilink AS4000 User ManualAbout MenuTo access the DS-3 Module About Menu, from the Main Menu:• Select Node Summary• Select T3• and th

Strany 28 - Configure the

Verilink AS4000 User Manual 8-1Chapter8Test Access Module (TAM)This chapter describes the Test Access Module.Test Access Module Configuration Use the

Strany 29 - 1. Press E

Test Access Module (TAM)8-2 Verilink AS4000 User ManualTest Access Module Configuration MenuUse this menu to configure control leads, select electrica

Strany 30

Test Access Module (TAM)Verilink AS4000 User Manual 8-3Data The options are Normal or Inverted. Inverted causes ones to be sent as zeros and zeros to

Strany 31

Test Access Module (TAM)8-4 Verilink AS4000 User ManualDiagnostics MenuTo view and perform diagnostics with the TAM, navigate to the TAM Diagnostics M

Strany 32

Test Access Module (TAM)Verilink AS4000 User Manual 8-5Where supported, AS4000 products implement a bi-directional V.54 loopback.Remote Loop Remote Lo

Strany 33

Test Access Module (TAM)8-6 Verilink AS4000 User ManualFigure 8-4 V.54 LoopbackThe above diagram refers to local and remote loops on the Diagnostics M

Strany 34 - Build Connections

Test Access Module (TAM)Verilink AS4000 User Manual 8-7Utilities MenuA brief description of each of the menus is provided in Table 8-3. In addition,

Strany 35

OverviewVerilink AS4000 User Manual 1-3• Generates and stores non-service-affecting T1 and T3 circuit performance data for circuit analysis and mainte

Strany 36 - More Information

Test Access Module (TAM)8-8 Verilink AS4000 User ManualFigure 8-6 TAM Utilities Menu TAM UTILITIESDUMP MEMORYCHANGE MEMORYBUFFER WATCHBACKP

Strany 37 - Hardware Installation

Test Access Module (TAM)Verilink AS4000 User Manual 8-9About MenuFigure 8-7 About Menu Table 8-4 About Menu.VVVVeeeerilinrilinrilinrilink k k k CorpCo

Strany 38 - Shelf Mounting

Test Access Module (TAM)8-10 Verilink AS4000 User Manual

Strany 39 - Installing Power Supplies

Verilink AS4000 User Manual 9-1Chapter9Octal DS-1/E1The Octal DS-1/E1 module manages and combines up to 8 T1 or 8 E1 data streams (voice, data and vid

Strany 40 - Rear Interface

Octal DS-1/E19-2 Verilink AS4000 User ManualFigure 9-1 Node Summary Menu NOTE:If the slot does not show a Configured Type, refer to “Slot Configuratio

Strany 41 - Application Card

Octal DS-1/E1Verilink AS4000 User Manual 9-3Octal DS-1/E1 Main MenuThe Octal T1/E1 Main Menu provides options that enable you to configure the Octal D

Strany 42 - AS4000 Cabling

Octal DS-1/E19-4 Verilink AS4000 User ManualFigure 9-3 Links Configuration Menu 4. To configure all parameters for each link, place your cursor on a l

Strany 43 - Network

Octal DS-1/E1Verilink AS4000 User Manual 9-5Table 9-1 Link Configuration FieldsField DescriptionLink Number Displays the link number selected from the

Strany 44

Octal DS-1/E19-6 Verilink AS4000 User ManualTable 9-2 Link Configuration Fields (continued)Octal DS-1/E1 Diagnostics• Line Diagnostics Center• Backpla

Strany 45 - System Menus

Octal DS-1/E1Verilink AS4000 User Manual 9-7Figure 9-5 Diagnostics Menu Upon selecting the Line Diagnostics Center, the Diagnostics Manager Menu appea

Strany 46 - Navigation Keys

Overview1-4 Verilink AS4000 User ManualConsole ControlThe system console provides control of the network from the central site. System configuration a

Strany 47 - Procedures

Octal DS-1/E19-8 Verilink AS4000 User ManualFigure 9-7 Octal DS-1/E1 LoopsNOTE:The Payload Loop is different than the Line Loop in that it only loops

Strany 48 - System Menu Tree

Octal DS-1/E1Verilink AS4000 User Manual 9-9Table 9-4 Hot Keys“[B]ert”Pseudo-random bit error test patterns“[L]oop”Allows you to set different loopbac

Strany 49 - Main Menu

Octal DS-1/E19-10 Verilink AS4000 User Manual[B]ertThe BERT Select Screen has a list of several test patterns.Figure 9-8 Diagnostics BERT Select Menu

Strany 50 - Node Summary Menu

Octal DS-1/E1Verilink AS4000 User Manual 9-11[L]oopThe Loop Select Menu has a list of several loopback options, including Local, Line, Analog, Remote,

Strany 51 - Connections Map Manager Menu

Octal DS-1/E19-12 Verilink AS4000 User Manual[E]xposeThe Expose Menu displays the real-time or current status of the DS-1/E1 link.Figure 9-10 Expose M

Strany 52 - Connection

Octal DS-1/E1Verilink AS4000 User Manual 9-13Table 9-5 Insert Error Options 1 - 9CAS Multiframe CRC-6MultiframePRBSFBitFrame AlignmentLine Code Violat

Strany 53 - Table 4-2

Octal DS-1/E19-14 Verilink AS4000 User ManualESF [S]tatisticsThe ESF Statistics Menu enables you to access both current and 24-hour ESF Statistics. T

Strany 54

Octal DS-1/E1Verilink AS4000 User Manual 9-15ESF [R]egistersThe ESF Registers Menu gives the same information as the ESF Statistics, but it is broken

Strany 55 - Connection Filter

Octal DS-1/E19-16 Verilink AS4000 User Manual1. Place your cursor on any Active link in the Diagnostics Manager Menu and type "R". A new me

Strany 56 - Connection Menu

Octal DS-1/E1Verilink AS4000 User Manual 9-17ProcedureTo access the G.826 Statistics screen:1. Place your cursor on any Active link in the Diagnostics

Strany 57

OverviewVerilink AS4000 User Manual 1-5System ComponentsThe standard components of the AS4000 system include the shelf, power modules, a System Manage

Strany 58 - Map Menu

Octal DS-1/E19-18 Verilink AS4000 User ManualFigure 9-14 Monitor Backplane Integrity Menu This screen is intended as a diagnostic tool for the manufa

Strany 59 - Map Definition

Octal DS-1/E1Verilink AS4000 User Manual 9-19Figure 9-15 Monitor Backplane Status Menu NOTE:The fields shown in this menu are the default settings an

Strany 60 - Time and Day

Octal DS-1/E19-20 Verilink AS4000 User ManualThe following hot keys invoke additional screens and/or functions:• [I] = Card In Service - places the ca

Strany 61 - Date and Time

Octal DS-1/E1Verilink AS4000 User Manual 9-21Figure 9-17 System Manager Interface Status The System Manager Interface Status is a view-only screen th

Strany 62 - Database Menu

Octal DS-1/E19-22 Verilink AS4000 User ManualFigure 9-18 Reset Device 5. Upon resetting the device, type "X". A new message appears: Rese

Strany 63 - Host File Name

Octal DS-1/E1Verilink AS4000 User Manual 9-23Figure 9-19 About Menu The About fields are described in Table 9-10.Table 9-10 About Field DescriptionsV

Strany 64

Octal DS-1/E19-24 Verilink AS4000 User Manual

Strany 65 - System Configuration Menu

Verilink AS4000 User Manual 10-1Chapter10Quad OCUThe Quad OCU (Office Channel Unit) module supports up to 4 DDS (Digital Dataphone Service) data strea

Strany 66 - Source Menu

Quad OCU10-2 Verilink AS4000 User ManualNOTE:If the slot does not show a Configured Type, refer to “Slot Configuration” in Chapter 4 of this manual.Th

Strany 67 - Users Menu

Quad OCUVerilink AS4000 User Manual 10-3Figure 10-3 Configuration Menu 4. To configure a port, place your cursor on a port number field and press ENTE

Strany 68 - Addresses

Overview1-6 Verilink AS4000 User ManualThe rear interface card provides the connectors for the various interfaces (RS-530, T1, XDSL, DS3, etc.). The i

Strany 69

Quad OCU10-4 Verilink AS4000 User ManualTable 10-1 Port Configuration FieldsQuad OCU DiagnosticsDiagnostics are used for troubleshooting problems or f

Strany 70 - SNMP Agent

Quad OCUVerilink AS4000 User Manual 10-5Figure 10-6 Line Diagnostics Menu The Diagnostics Manager fields are described in Figure 10-2.Table 10-2 Diagn

Strany 71 - Node Name

Quad OCU10-6 Verilink AS4000 User ManualCommandsThe following commands invoke additional screens and/or functions.Table 10-3 Hot Keys Loopback TypesAv

Strany 72 - Events Menu

Quad OCUVerilink AS4000 User Manual 10-7Quad OCU UtilitiesTo access the Quad OCU Utilities, follow these steps:1. From the AS4000 Main Menu, select No

Strany 73 - Display Event

Quad OCU10-8 Verilink AS4000 User ManualFigure 10-9 System Manager Interface StatusThe System Manager Interface Status is a view-only display that sh

Strany 74

Quad OCUVerilink AS4000 User Manual 10-9Reset DeviceReset Device causes the card to initialize in the same manner as power up. During this boot-up cy

Strany 75

Quad OCU10-10 Verilink AS4000 User ManualAbout MenuProcedureTo display identification information for the Quad OCU module:1. From the Main Menu, selec

Strany 76 - MIB Table

Verilink AS4000 User Manual 11-1 Chapter11Quad DS-1 with xDSLThe AS4000 Quad DS-1 Module can operate in an HDSL or SDSL mode using an optional xDSL re

Strany 77

Quad DS-1 with xDSL11-2 Verilink AS4000 User ManualFigure 11-1 xDSL Interface Module Without Daughter Cards4. Set the two 4-position dipswitches as s

Strany 78 - IP Route Table

Quad DS-1 with xDSLVerilink AS4000 User Manual 11-3Figure 11-2 xDSL Interface Module with Daughter Boards Fitted5. Continue to use the ground strap a

Strany 79 - Dump IP route

OverviewVerilink AS4000 User Manual 1-7• AUI—An Ethernet LAN port labeled AUI provides a DB-15 pin AUI connection. • Term Ports—Two console ports, lab

Strany 80 - ARP Table Utility

Quad DS-1 with xDSL11-4 Verilink AS4000 User ManualThe first pair of wires is connected to T1 and R1. When used, the second pair is connected to T2 an

Strany 81 - Settings

Quad DS-1 with xDSLVerilink AS4000 User Manual 11-5xDSL ConfigurationNOTE:In order to view the menus associated with the xDSL application, you must ha

Strany 82 - Timeslots

Quad DS-1 with xDSL11-6 Verilink AS4000 User ManualFigure 11-5 xDSL Port Configuration Menu Use the Port Configuration Menu to select a port which ha

Strany 83

Quad DS-1 with xDSLVerilink AS4000 User Manual 11-7Figure 11-6 xDSL Port Configuration Menu Table 11-1 xDSL Port Configuration Menu.Viewing Span Stat

Strany 84 - Devices Software

Quad DS-1 with xDSL11-8 Verilink AS4000 User ManualFigure 11-7 Span Status Elements of the Span Status display are defined in Table 11-2.Table 11-2

Strany 85 - Reset All Channel

Quad DS-1 with xDSLVerilink AS4000 User Manual 11-9Set ClockUse Set Clock to define the current time and date. This assures that alarm messages will h

Strany 86

Quad DS-1 with xDSL11-10 Verilink AS4000 User ManualSystem SettingsType "C" to access the System Settings Menu.Figure 11-9 System Settings

Strany 87 - Who Am I

Quad DS-1 with xDSLVerilink AS4000 User Manual 11-11LOOPLOOPLOOPLOOPBBBBACK (ACK (ACK (ACK (TTTT)IMEOU)IMEOU)IMEOU)IMEOUTTTT:::: Sets an optional time

Strany 88

Quad DS-1 with xDSL11-12 Verilink AS4000 User ManualLoopback ModeUse the Loopback Mode Menu to put up and take down loopbacks. The network type loopba

Strany 89 - Quad DS-1 Module

Quad DS-1 with xDSLVerilink AS4000 User Manual 11-13Performance DataUse the Performance Data Menu to view 24 hours of performance statistics. The disp

Strany 90 - DS-1 Port

Overview1-8 Verilink AS4000 User ManualSpecificationsTable 1-3 lists specifications for the AS4000, and Table 1-4 lists power supply specifications.Ta

Strany 91 - Registers

Quad DS-1 with xDSL11-14 Verilink AS4000 User ManualPerformance HistoryPerformance History displays a summary of errored and unavailable seconds for t

Strany 92

Verilink AS4000 User Manual 12-1 Chapter12Octal Voice ModuleThe AS4000 Octal Voice Module supports up to 8 voice channel connections. Each voice chann

Strany 93 - ESF Registers

Octal Voice Module12-2 Verilink AS4000 User ManualE&M Interface Module OptionsThe E&M Interface Module has options which are set using strips

Strany 94

Octal Voice ModuleVerilink AS4000 User Manual 12-3Setting Berg JumpersFor each of the eight voice channel inputs, one strip of ganged Berg jumpers is

Strany 95

Octal Voice Module12-4 Verilink AS4000 User ManualOctal Voice with E&M Rear Module MenusThis section describes the menus used for configuration, t

Strany 96

Octal Voice ModuleVerilink AS4000 User Manual 12-5Figure 12-3 Voice Module Configuration Menu Use the Octal Voice Card Configuration Menu to select a

Strany 97 - Quad DS-1 Utilities Menu

Octal Voice Module12-6 Verilink AS4000 User ManualTable 12-2 details the options on the Configuration Submenu.Table 12-2 Octal Voice Configuration Sub

Strany 98 - Voice Control

Octal Voice ModuleVerilink AS4000 User Manual 12-7Octal Voice with FXS/PLAR Rear Module MenusThis section describes the menus used for configuration,

Strany 99 - Voice Control Signals

Octal Voice Module12-8 Verilink AS4000 User ManualFigure 12-6 Voice Module Configuration Menu Use the Octal Voice Card Configuration Menu to select a

Strany 100 - About Menu

Octal Voice ModuleVerilink AS4000 User Manual 12-9Table 12-2 details the options on the Configuration Submenu.Table 12-3 Octal Voice Configuration Sub

Strany 101 - Quad Port Sync Data Module

OverviewVerilink AS4000 User Manual 1-9Table 1-4 AS4000 Power SuppliesAS4011 AS4004DC Inputs:-48VDC Power Input (range 38 to 60 VDC), 250W max.(Approv

Strany 102 - Configuration Menu

Octal Voice Module12-10 Verilink AS4000 User ManualOctal Voice with FXO/DPT Rear Module MenusThis section describes the menus used for configuration,

Strany 103 - More About

Octal Voice ModuleVerilink AS4000 User Manual 12-11Figure 12-9 Voice Module Configuration Menu Use the Octal Voice Card Configuration Menu to select

Strany 104 - Crossover Timing

Octal Voice Module12-12 Verilink AS4000 User ManualTable 12-2 details the options on the Configuration Submenu.Table 12-4 Octal Voice Configuration Su

Strany 105 - Diagnostics Menu

Octal Voice ModuleVerilink AS4000 User Manual 12-13DiagnosticsThe Diagnostics Menu, Figure 12-11, presents a summary of test and in-service/out-of-ser

Strany 106 - Loopbacks

Octal Voice Module12-14 Verilink AS4000 User ManualFigure 12-12 Octal Voice Diagnostics Submenu Table 12-5 Voice Module Diagnostics Test Types.VVVVeee

Strany 107 - Utilities Menu

Octal Voice ModuleVerilink AS4000 User Manual 12-15Figure 12-13 illustrates the three major types of voice module loopbacks and indicates the location

Strany 108 - Interface Display

Octal Voice Module12-16 Verilink AS4000 User ManualUtilitiesThe Utilities Menu offers access to system level functions. Figure 12-14 Octal Voice Utili

Strany 109

Octal Voice ModuleVerilink AS4000 User Manual 12-17AboutThe About Menu presents a screen of information relating to the Octal Voice Module.Figure 12-1

Strany 110

Octal Voice Module12-18 Verilink AS4000 User Manual

Strany 111 - DS-3 Module

Verilink AS4000 User Manual A-1AppendixATFTP and TelnetThis appendix describes using the TFTP application for firmware upgrades of the AS4000. TFTP A

Strany 112 - T1 Configuration

ii Verilink AS4000 User ManualCopyright NoticeCopyright  2000 Verilink Corporation. All rights reserved.This document does not create any express or

Strany 113

Overview1-10 Verilink AS4000 User Manual

Strany 114 - T1 Channel

A-2 Verilink AS4000 User Manual

Strany 115 - T3 Port

Verilink AS4000 User Manual B-1AppendixBInterfaces and CablesThe AS4000 requires cables and connectors to attach devices to the AS4000 interfaces (po

Strany 116

B-2 Verilink AS4000 User ManualTerminal PortUse the terminal port to connect to an external terminal providing RJ-11 modular connectors. Table B-2 Te

Strany 117 - Options Menu

Verilink AS4000 User Manual B-3Application Module InterfacesThe standard serial port interface provides (4) DB-25 pin receptacles supporting RS-232, R

Strany 118

B-4 Verilink AS4000 User ManualDB-25 to V.35Cable AdaptersV.35 interface applications require a DB-25 to V.35 cable adapter. Optional cable adapters a

Strany 119 - Line Diagnostics

Verilink AS4000 User Manual B-5Quad DS-1 T1InterfaceThe Quad DS-1 T1 interface provides (4) RJ-48C modular connectors. The pin assignments are listed

Strany 120 - T1 Loopbacks

B-6 Verilink AS4000 User Manual

Strany 121

IndexVerilink AS4000 User Manual Index-1Symbols# of Valid intervals 9-15AAboutchecksum 9-23, 10-10front card rev 9-23, 10-10front card type 9-23rear c

Strany 122

Index-2 Verilink AS4000 User Manualmid-plane 1-3Mid-Plane Design 1-3mounting brackets 3-2NNavigation Keys 4-2Node Summary Menu 4-6OOctal 9-20configur

Strany 123 - Test Access Module (TAM)

Affidavit for the Connection of Customer Premises Equipment to 1.544 Mbps and/or Subrate Digital ServicesFor work to be performed in the certified ter

Strany 124 - Test Access

Verilink AS4000 User Manual 2-1Chapter2Quick Set-Up GuideThis chapter is a step-by-step guide for installing the AS4000. For the purpose of this chapt

Strany 125

VERILINK CORPORATION127 JETPLEX CIRCLE, MADISON, ALABAMA 35758TEL: (800) 837-4546June 2000P/N 880-503457-001-C

Strany 126

Quick Set-Up Guide2-2 Verilink AS4000 User ManualFigure 2-1 Example NetworkWork FlowThe four major tasks of the installation are:• Physical Installati

Strany 127

Quick Set-Up GuideVerilink AS4000 User Manual 2-3Figure 2-2 Example Work Flow

Strany 128 - Figure 8-4 V.54 Loopback

Quick Set-Up Guide2-4 Verilink AS4000 User ManualStep-by-StepTo install this example configuration perform the following steps.PhysicalInstallation1.

Strany 129

Quick Set-Up GuideVerilink AS4000 User Manual 2-5Figure 2-3 Main Menu Configure System8. Select System Configuration. The System Configuration Menu ap

Strany 130 - TAM UTILITIES

Quick Set-Up Guide2-6 Verilink AS4000 User ManualFigure 2-5 Users Menu 10. Select Port IP Addresses. The Port IP Addresses Menu appears.Figure 2-6 Por

Strany 131

Quick Set-Up GuideVerilink AS4000 User Manual 2-711. Set the IP encapsulation to Ethernet II. Set the IP address and subnet mask per the information p

Strany 132

Quick Set-Up Guide2-8 Verilink AS4000 User ManualFigure 2-8 SNMP Configuration Menu 14. Exit from the System Configuration Menu by pressing "X&qu

Strany 133 - Octal DS-1/E1

Quick Set-Up GuideVerilink AS4000 User Manual 2-9Figure 2-9 Node Summary Menu 16. The T3 module is already under the cursor because it is in slot 1. P

Strany 134

Verilink AS4000 User Manual iiiFCC User RequirementsThis information is provided to ensure that you comply with the Federal Communications Commission

Strany 135 - Octal DS-1/E1 Main Menu

Quick Set-Up Guide2-10 Verilink AS4000 User ManualFigure 2-11 DS-3 Configuration Menu 18. Select the T1 Configuration Menu and set the first T1 circui

Strany 136

Quick Set-Up GuideVerilink AS4000 User Manual 2-11Figure 2-12 T3 Port Configuration Menu 21. On the Node Summary Menu, use the SPACE BAR to navigate t

Strany 137

Quick Set-Up Guide2-12 Verilink AS4000 User ManualFigure 2-14 Quad Sync Data Port Configuration Menu 23. At the Node Summary Menu, select the next ins

Strany 138 - Octal DS-1/E1 Diagnostics

Quick Set-Up GuideVerilink AS4000 User Manual 2-13Figure 2-16 Quad DS-1 T1 Port Configuration Menu 25. Set all four T1 ports to ESF framing, B8ZS line

Strany 139 - Loopback Types

Quick Set-Up Guide2-14 Verilink AS4000 User ManualBuild Connections27. On the Connection Maps Manager Menu, select Active Map. The current map configu

Strany 140 - Hot Keys

Quick Set-Up GuideVerilink AS4000 User Manual 2-15Figure 2-19 Map Configuration Menu 32. Add like connections for the other three T1 ports on the Quad

Strany 141

Quick Set-Up Guide2-16 Verilink AS4000 User Manual34. Map the first four timeslots of the first T1 port on the Quad DS-1 Module in slot 8 to the four

Strany 142 - Procedure

Verilink AS4000 User Manual 3-1Chapter3Hardware InstallationThis chapter provides detailed information for AS4000 hardware installation. This chapter

Strany 143

Hardware Installation3-2 Verilink AS4000 User ManualUnpack the AS4000 components and inspect for possible damage:• Shelf units• Power supplies• All ap

Strany 144 - Keys 1 thru 9

Hardware InstallationVerilink AS4000 User Manual 3-3Figure 3-1 Shelf Mounting37. Position the shelf at the designated location within the equipment ra

Strany 145

iv Verilink AS4000 User ManualEnglish DANGER!The battery can explode if incorrectly replaced! Replace only with the same or equivalent type recommende

Strany 146 - ESF [S]tatistics

Hardware Installation3-4 Verilink AS4000 User ManualWARNINGVerilink AC power supplies require a three-prong grounded receptacle. Do not use an adapte

Strany 147 - ESF [R]egisters

Hardware InstallationVerilink AS4000 User Manual 3-51. Slide the rear connector module into the back of the assigned shelf slot, ensuring both connect

Strany 148

Hardware Installation3-6 Verilink AS4000 User ManualAS4000 CablingAll AS4000 cables meet national and international standards. Figure 3-4 provides an

Strany 149 - Backplane Check

Hardware InstallationVerilink AS4000 User Manual 3-7Network ConnectionsConnect the network cables only after the individual modules have been configur

Strany 150 - System Status

Hardware Installation3-8 Verilink AS4000 User Manual

Strany 151

Verilink AS4000 User Manual 4-1Chapter4System MenusThis chapter describes the AS4000 System Menu structure. It does not describe the individual module

Strany 152 - Utilities

System Menus4-2 Verilink AS4000 User ManualNOTE:The default is no user name and no password. Press the ENTER key twice to log in for the first time. I

Strany 153 - Reset Device

System MenusVerilink AS4000 User Manual 4-3Other fields require you to enter information, these will present a field with underscore characters after

Strany 154

System Menus4-4 Verilink AS4000 User ManualSystem Menu TreeThe AS4000 uses a hierarchical menu tree. Figure 4-3 illustrates the first two levels of me

Strany 155

System MenusVerilink AS4000 User Manual 4-5Main MenuThe Main Menu is the top-level menu for the AS4000. This menu provides access to the Node Summary

Strany 156

Verilink AS4000 User Manual vCanadian RequirementsThis digital apparatus does not exceed the Class A limits for radio noise emissions from digital ap

Strany 157 - Quad OCU

System Menus4-6 Verilink AS4000 User ManualNode Summary MenuThe Node Summary Menu structure provides access to any modules physically located within t

Strany 158 - Configuring the Quad OCU

System MenusVerilink AS4000 User Manual 4-7Connections Map Manager MenuThe Connection Maps Manager Menu provides access to six submenus, as shown in F

Strany 159

System Menus4-8 Verilink AS4000 User ManualFigure 4-7 Active Maps Menu Add or DeleteConnectionTo add or delete a connection, position the cursor on a

Strany 160 - Quad OCU Diagnostics

System MenusVerilink AS4000 User Manual 4-9Figure 4-8 Add New Connection Menu The commands used to add a new connection are listed in Table 4-1.Table

Strany 161 - Figure 10-6

System Menus4-10 Verilink AS4000 User ManualCAUTIONIn some cases, the same data rate can be achieved with two different DS0 quantities, one with 56 kb

Strany 162

System MenusVerilink AS4000 User Manual 4-11Connection Filter Configuration You can arrange to view specific data by using the Filter Menu. The menu o

Strany 163 - Quad OCU Utilities

System Menus4-12 Verilink AS4000 User Manual• Filter by slot/port• Starting slot/port/timeslotFigure 4-9 Connection Filter Configuration Menu Table 4-

Strany 164

System MenusVerilink AS4000 User Manual 4-13Figure 4-10 Change Connection Screen Test A Connection MenuThis menu is used to select a test type and to

Strany 165

System Menus4-14 Verilink AS4000 User ManualFigure 4-11 Test Connections Screen The Tester slot.port field is used to define the address (slot and por

Strany 166

System MenusVerilink AS4000 User Manual 4-15Figure 4-12 Configuration Maps Menu Up to five maps can be configured, but only one map can be active at a

Strany 167 - Quad DS-1 with

vi Verilink AS4000 User Manual•Never push objects of any kind into the shelves. They may touch dangerous voltage points or short out parts that could

Strany 168 - Figure 11-1

System Menus4-16 Verilink AS4000 User ManualFigure 4-13 Map Definition MenuIn the example Map Definition Menu shown above, the user has pressed the E

Strany 169 - Connecting Local

System MenusVerilink AS4000 User Manual 4-17Figure 4-14 Time and Day Configuration Menu The Active Map field is a read-only field. It shows which map

Strany 170

System Menus4-18 Verilink AS4000 User ManualFigure 4-15 Date and Time Menu The Set Time Menu has seven parameters: month, day, year, hour, minute, sec

Strany 171 - Select DSL Port

System MenusVerilink AS4000 User Manual 4-19Figure 4-16 Save and Restore Database Menu NOTE:This parameter can be accessed from both the System Config

Strany 172

System Menus4-20 Verilink AS4000 User Manual3. Select “Save” and exit the menu.4. Press Y at the confirmation screen. The “Restore” command gathers th

Strany 173 - Viewing Span

System MenusVerilink AS4000 User Manual 4-21System Configuration MenuThe System Configuration Menu (Figure 4-17) provides access to submenus for confi

Strany 174

System Menus4-22 Verilink AS4000 User ManualFigure 4-18 Slot Configuration Menu Use this menu to configure which types of modules are present in the A

Strany 175 - Set Clock

System MenusVerilink AS4000 User Manual 4-23Figure 4-19 System Clock Source Menu In the example menu shown above, the primary clock source is the DS3

Strany 176 - System Settings

System Menus4-24 Verilink AS4000 User ManualFigure 4-20 Users Menu Port IP AddressesThe IP Addresses Menu is used to configure the TCP/IP stack in the

Strany 177

System MenusVerilink AS4000 User Manual 4-25Figure 4-21 IP Addresses Menu Table 4-4 Port IP Addresses VerVerVerVeriiiilink link link link CCCCorpororp

Strany 178 - Loopback Mode

Table of ContentsVerilink AS4000 User Manual viiOverview...

Strany 179 - Performance

System Menus4-26 Verilink AS4000 User ManualSNMP Agent ConfigurationThe SNMP Agent Configuration Menu is used to configure the AS4000 to work with an

Strany 180

System MenusVerilink AS4000 User Manual 4-27Table 4-5 SNMP Configuration CommandsDate and TimeUse the Date and Time Menu to set the system clock in th

Strany 181 - Octal Voice Module

System Menus4-28 Verilink AS4000 User ManualFigure 4-24 Node Name Menu Events MenuUse the Events Menu to monitor and display system events. This menu

Strany 182

System MenusVerilink AS4000 User Manual 4-29Figure 4-26 Monitor Events Display Display Event LogSelect Display Event Log (Figure 4-27) to view the mos

Strany 183 - Setting Berg

System Menus4-30 Verilink AS4000 User ManualFigure 4-27 Display Event Log Screen Event Configuration MenuSelect Event Configuration Menu (Figure 4-28)

Strany 184

System MenusVerilink AS4000 User Manual 4-31Figure 4-28 Event Configuration Menu Utilities MenuUse the Utilities Menu to access system routing utiliti

Strany 185 - to access a

System Menus4-32 Verilink AS4000 User ManualFigure 4-30 Copy File System Screen Switchover SMCsUse this command to switchover from the active System M

Strany 186

System MenusVerilink AS4000 User Manual 4-33Figure 4-32 MIB Table PINGAfter you enter the node address, count, and length, the unit responds with PING

Strany 187

System Menus4-34 Verilink AS4000 User ManualFigure 4-33 PING Menu Table 4-6 Ping MenuIP Route TableThis table is used by the AS4000 to map the LAN net

Strany 188

System MenusVerilink AS4000 User Manual 4-35Figure 4-34 .IP Route Table Menu Show IP RouteUse this field to request routing information for a specific

Strany 189

viii Verilink AS4000 User ManualSystem Menus...

Strany 190

System Menus4-36 Verilink AS4000 User ManualFigure 4-36 Dump IP Route Table Table 4-7 Dump IP Route TableARP Table UtilityDisplayARP (Address Resoluti

Strany 191

System MenusVerilink AS4000 User Manual 4-37Figure 4-37 ARP Table Selection Table 4-8 ARP Table DisplayReturn to Default SettingsThis parameter resets

Strany 192

System Menus4-38 Verilink AS4000 User ManualBackplane Timeslots DisplayThe Backplane Timeslots Display is a read-only diagnostic utility which provide

Strany 193 - Diagnostics

System MenusVerilink AS4000 User Manual 4-39Table 4-9 Flag DefinitionInitialize SMC Rear Card ModemTo access the Initialize SMC Rear Card Modem utilit

Strany 194

System Menus4-40 Verilink AS4000 User ManualFigure 4-41 File System Debug Counters Download Devices SoftwareThe Download Devices Software Menu allows

Strany 195

System MenusVerilink AS4000 User Manual 4-41Figure 4-42 Download Devices Software Reset All Channel CardsThis command resets all AS4000 application mo

Strany 196

System Menus4-42 Verilink AS4000 User ManualAbout MenuThe About Menu branches to two submenus.• System Profile• Who Am ISystem ProfileThe System Profi

Strany 197

System MenusVerilink AS4000 User Manual 4-43Who Am IThe Who Am I Menu may be used to examine the access level of the current user. After inputting the

Strany 198

System Menus4-44 Verilink AS4000 User Manual

Strany 199 - TFTP and Telnet

Verilink AS4000 User Manual 5-1Chapter5Quad DS-1 ModuleThe AS4000 module which is labelled Quad DS-1 Module on its front panel presents console menus

Strany 200

Verilink AS4000 User Manual ixQuad DS-1 Module ...

Strany 201 - Interfaces and Cables

Quad DS-1 Module5-2 Verilink AS4000 User ManualDS-1 Port ConfigurationThe Quad DS-1 configuration files are stored on the System Controller. Thus, whe

Strany 202 - Phone Line Port

Quad DS-1 ModuleVerilink AS4000 User Manual 5-3Viewing ESF Statistics and RegistersTo view the ESF Statistics and Registers, select the Statistics men

Strany 203 - Interfaces

Quad DS-1 Module5-4 Verilink AS4000 User ManualFigure 5-4 Quad DS-1 ESF Statistics Display Access both current and 24-hour ESF statistics from this sc

Strany 204 - Cable Adapters

Quad DS-1 ModuleVerilink AS4000 User Manual 5-5ESF RegistersIn accordance with industry standards such as AT&T 54016 and ANSI T1.403, the Quad DS-

Strany 205 - Interface

Quad DS-1 Module5-6 Verilink AS4000 User ManualThe ESF Registers Menu gives the same information as the ESF Statistics Menu but it is broken down by p

Strany 206

Quad DS-1 ModuleVerilink AS4000 User Manual 5-7Diagnostics MenuThe Diagnostics Menu is used to perform loopbacks and tests for the purpose of verifyin

Strany 207

Quad DS-1 Module5-8 Verilink AS4000 User ManualSeconds in test This read-only count represents the number of seconds the Quad DS-1 module was in test.

Strany 208

Quad DS-1 ModuleVerilink AS4000 User Manual 5-9Quad DS-1 Utilities MenuThe Quad DS-1 Utilities Menu offers six functions. Figure 5-8 Quad DS-1 Utiliti

Strany 209

Quad DS-1 Module5-10 Verilink AS4000 User ManualFigure 5-9 Monitor System Manager Clock DisplayVoice Control SignalsYou can view real-time voice signa

Strany 210 - VERILINK CORPORATION

Quad DS-1 ModuleVerilink AS4000 User Manual 5-11Figure 5-10 Voice Control Signal Bit DisplayMeaningful only for timeslots being used for ordinary Puls

Komentáře k této Příručce