TRANSPORT
®
1051-2 Chassis Rear Panel Pinouts
Pin T1 D/I T1 NET NMS IN NMS OUT Alarm /Power Net/Ext. Clk
1 Data Out Data In Not Used Not Used 48 V Return Net In (Tip)
2 Data Out Data In Signal Ground Signal Ground Signal Ground Net In (Ring)
3 Not Used Not Used Data Out Data Out -48 VDC Net Out (Tip)
4 Data In Data Out Data In Not Used Frame Ground Net Out (Ring)
5 Data In Data Out Signal Ground Signal Ground Alarm Contact Station Clk (Ring)
6 Not Used Not Used Not Used Not Used Alarm Common Station Clk (Tip)
7, 8 Chassis Ground Chassis Ground Not Applicable Not Applicable Not Applicable Not Applicable
1
61
1
1
6
1
8
1
8
NMS IN
6
NMS OUT
T1 D/I
NETWORK
1
14
13
25
DTE
PORT
48 VDC
ALARM/POWER
NTWK/EXT CLK
Switch S4
S4-1:Network Framing
Dn
: ESF Up: D4
S4-2:Network Coding
Dn: AMI Up
: B8ZS
S4-5:Channel Assignment - Used to
select DS0 channels (used with Switch
S7). See Table S7 Bit Rates (kbps).
S4-8:Channel Assignment - Used to
select channel assignment mode (used
with Switch S7).
Dn
: Contiguous Up: Alternate
S4-3 S4-4 Network LBO
Dn
Dn 0 dB
Up Dn -7.5 dB
Dn Up -15.0 dB
Up Up -22.5 dB
S4-6 S4-7 Timing Source
Dn Dn Internal Settings
Up Dn Network
Dn Up T1 DTE
Up Up High-speed port
8654321
D
n
U
p
7
127 Jetplex Circle
Madison, Alabama 35758
Sales and Marketing
800-926-0085
205-772-3770
info@txport.com
Returns/RMA
800-926-0085, ext. 2227
Technical Support
800-285-2755
205-772-3770
support@txport.com
High-speed DTE Pinout
DB-25
25-pin
A/B
Common
Name
EIA-530
25-pin
A/B
RS-449
37-pin
A/B
V. 35
34-pin
A/B
1 Frame Ground 1 1 A
7 Signal Ground 7 19 B
2/14 Transmit Data 2/14 4/22 P/S
3/16 Receive Data 3/16 6/24 R/T
4/19 Request to
Send
4/19 7/25 C
5/13 Clear to Send 5/13 9/27 D
6/22 Data Set
Ready
6/22 11/29 E
20/23 Data Term
Ready
20/23 12/30 H
8/10 Data Carrier
Detect
8/10 13/31 F
15/12 Transmit
Clock
15/12 5/23 Y/AA
17/9 Receive Clock 17/9 8/26 V/X
24/11 Terminal
Timing
24/11 17/35 U/W
Switch S6
S6-7:Used to set the multiplier with
Switch S7.
Dn
: ×64 kbps Up: ×56 kbps
S6-8:Not used.
S6-1 S6-2 NMS Port Rate
Dn
Dn 19200 bps
Up Dn 9600 bps
Dn Up 2400 bps
Up Up 1200 bps
S6-3 S6-4 SUPV Port Rate
Dn
Dn 19200 bps
Up Dn 9600 bps
Dn Up 2400 bps
Up Up 1200 bps
S6-5 S6-6 Power-up Mode
Dn
Dn Switch Settings
Up Dn RAM
Dn Up Network Manager
Up Up ROM
8654321
D
n
U
p
7
Switch S8 (T1 DTE)
If equipped, this board is located on
the opposite side of the circuit board
shown in Figure Top-edge View of the
3001.
S8-1:Used to set the line framing.
Dn: ESF Up
:D4
S8-2:Used to set the line coding.
Dn
: AMI Up: B8ZS
S8-6, S8-7, and S8-8: Not used.
S8-3 S8-4 S8-5 DTE LBO
Dn
Dn Dn 0 - 110 ft
Up Dn Dn 110 - 220 ft
Dn Up Dn 220 - 330 ft
Up Up Dn 330 - 440 ft
Dn Dn Up 440 - 550 ft
Up Dn Up 550 - 655 ft
Dn Up Up >655 ft
8654321
D
n
U
p
7
8654321
Dn Up
7
1
2
4
8
16
32
64
128
Binary values
0
0
0
0
0
0
0
0
LSB MSB
Address Switch S5
For reference, all DIP
switches are provided with
upper and lower boxes to
check the particular user
selection. Factory default set-
tings are shown underlined
.
S7 Bit Rates (kbps)
Switch
S7
w/S4-5 down
w/S4-5 up
×56 ×64 ×56 ×64
0 56 64 168 192
1 112 128 280 320
2 224 256 392 448
3 336 384 448 512
4 560 640 504 576
5 672 768 616 704
6 1008 1152 728 832
7 1120 1280 784 896
8 1232 1408 896 1024
9 1344 1536
1064 1216
20 of the 24 possible bit rate configura-
tions are available through Switch S7
(and Switch S4). The missing rates are
N×56 and N×64, where N=15, 17, 21,
and 23. All 24 rate configurations are
available through software control.
This 3-pin header straps the ACO alarm
contact. Position jumper over pins 1 and
2 for normally open
operation (closes on
alarm) or over pins 2 and 3 for normally
closed operation (opens on alarm).
NO
NC
1
2
3
Alarm Relay
Top-edge View of the 3001
0
1
2
3
4
5
6
7
9
8
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Alarm
S5 S4S6S7
Bantam Jacks
Receive signal from
the network
Monitor signal from
the network
Transmit signal
to the network
Monitor signal
from the DTE
Four front panel bantam test jacks are
provided for access to the T1 line on
the DTE side of the CSU. Two are used
for non-intrusive bridge monitoring of
the line in both directions (MON) and
two are used to insert into the line in
both directions (NET).