Verilink PRISM 3002 (34-00277) Product Manual Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Počítačový hardware Verilink PRISM 3002 (34-00277) Product Manual. Verilink PRISM 3002 (34-00277) Product Manual User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - CSU/DSU

i34-002772nd EditionPRISM 3002T1/FT1 CSU/DSU

Strany 2

1-4 GENERALDTE Port Loops: Bidirectional loop toward DTE and Net BERT: Multiple test patterns toward network or DTE port AlarmsActivation: Programmabl

Strany 3

Ordering Information 1-5OrderingInformationThe PRISM 3002 is available with a single V.35 data port (P/N F-3002-101-1110 is the default). Order

Strany 4

1-6 GENERAL

Strany 5 - Table of Contents

2INSTALLATIONThis chapter contains instructions for physically installing the Verilink PRISM 3002 in a 1024 chassis as well as information concerning

Strany 6 - Procedure

2-2 INSTALLATIONPortConnectionsThe front of the PRISM 3002 has one port connection: the Supervisory (SUPV), discussed on page 2-3. The rear of the PRI

Strany 7 - Introduction

Port Connections 2-3Data Port The Data Port provides connection to the customer equipment. Pinouts for the backplane connector and both high-spe

Strany 8 - Features

2-4 INSTALLATIONThe SUPV port bit rates are configured through Switch S1 (see SUPV Port Bit Rate on page 3-2) and programmed through the Management Po

Strany 9 - 1-3

Network Management 2-5Network ManagementNetwork management is performed through the SUPV port and the NMS port. these ports allow connection of

Strany 10 - 1-4 GENERAL

2-6 INSTALLATION

Strany 11 - Information

3HARDWARE CONFIGURATION AND TESTINGThis chapter contains general operating instructions for the Verilink PRISM 3002 front panel. The unit may be contr

Strany 12 - 1-6 GENERAL

iiCopyright NoticeCopyright © 1999 Verilink Corporation. All rights reserved.This document does not create any express or implied warranty about Veril

Strany 13 - NSTALLATION

3-2 HARDWARE CONFIGURATION AND TESTING NMS AddressSwitches S1-1 through S1-8 set the NMS address. When using the 3002 with an 8100A Site Controller, e

Strany 14 - Connections

Upgrading Software 3-3Supervisory Port The supervisory port serves several functions by allowing the connection of devices such as an 8100A Site

Strany 15 - Port Connections

3-4 HARDWARE CONFIGURATION AND TESTING

Strany 16 - Figure 2-3

4TERMINAL CONFIGURATION AND TESTINGThe terminal interface is an embedded firmware application program. This information can be accessed through the SU

Strany 17 - NMS Daisy-chain Arrangement

4-2 TERMINAL CONFIGURATION AND TESTINGIf the password is not available, note the date and time shown on the screen and contact Verilink Technical Supp

Strany 18 - 2-6 INSTALLATION

Cursor Controls 4-3Element ID Below the header (PRISM 3002), the Element ID is displayed. Refer to Element ID on page 4-22 for information. Men

Strany 19 - ONFIGURATION

4-4 TERMINAL CONFIGURATION AND TESTINGa letter key while holding down the Control key. Alternate commands may be freely mixed with the keyboard comman

Strany 20 - LSB MSBBinary values

Alarms Screen 4-5Alarms Screen The Alarms screen (Figure 4-4) allows viewing the current alarm status of the network and the DTE lines.NET Alarm

Strany 21 - Software

4-6 TERMINAL CONFIGURATION AND TESTINGDTE AlarmsThese status lines display the selected element’s current DTE signal alarm state (Table 4-3). Alarms a

Strany 22

Performance Screens 4-7PerformanceScreensThe Performance screens (Figure 4-5) display a detailed history of the continuously monitored error pa

Strany 23

iii4 The unit has been designed to prevent harm to the T1 network. If the telephone company findsthat the equipment is exceeding tolerable parameters,

Strany 24 - Figure 4-2

4-8 TERMINAL CONFIGURATION AND TESTINGTelco NETDisplay the telco performance registers for the network.Error EventsThis field displays the running tot

Strany 25 - Controls

Performance Screens 4-9The remaining lines of this screen show the data for any intervals containing errors. Interval 1 is the most recently st

Strany 26 - Field Types

4-10 TERMINAL CONFIGURATION AND TESTINGMaintenance ScreenThe Element Maintenance screen (Figure 4-6) allows performing loop-test and BERT functions on

Strany 27 - Alarms Screen

Maintenance Screen 4-11The type of T1 loop is chosen by toggling the spacebar and is executed by pressing Enter. NET PLB (Payload Loopback)The r

Strany 28

4-12 TERMINAL CONFIGURATION AND TESTINGFAR LLBA NET LLB can be activated on the far-end unit through this selection or through the front panel TEST bu

Strany 29 - Performance

Maintenance Screen 4-13causes the unit to transmit in-band V.54 fractional loop code toward the network in the port’s bandwidth. Port Unloop Pre

Strany 30 - (NO!) (YES)

4-14 TERMINAL CONFIGURATION AND TESTING% EFSThis ratio is derived from the number of error-free seconds divided by the number of seconds accumulated i

Strany 31 - 4-9

Configuration Screens 4-15LineParametersThe Line Parameters screen (Figure 4-7) allows reviewing and setting line parameters for the selected e

Strany 32 - Maintenance

4-16 TERMINAL CONFIGURATION AND TESTINGINTERNAL. The unit’s internal frequency standard is used for all timing. PORT 1. Timing is synchronized to th

Strany 33 - Network PLB

Configuration Screens 4-17AlarmConfigurationThe Alarm Configuration screen (Figure 4-8) allows reviewing and setting alarm-related thresholds f

Strany 34 - Network LLB

ivSafety PrecautionsWhen handling this equipment, follow these basic safety precautions to reduce the risk of electricshock and injury: • Follow all w

Strany 35 - Port Loop (bidirectional)

4-18 TERMINAL CONFIGURATION AND TESTINGOut of Frame SecondsA one-second period in which a frame sync loss occurred. BPV SecondsA one-second period in

Strany 36 - Configuration

Configuration Screens 4-19Rate MultiplierThe unit can operate at any data rate that is a multiple of 56 or 64 kbps. When N×64K is selected, the

Strany 37 - Line Parameters Screen

4-20 TERMINAL CONFIGURATION AND TESTINGInvert DataIn the invert mode (YES), transmit and receive data are inverted at the port interface. This functio

Strany 38

Configuration Screens 4-21StatusLists the current DBU status as either Disabled, Enabled, Active, Connecting, Disallowed, Dialing, Disconnectin

Strany 39 - Alarm Configuration Screen

4-22 TERMINAL CONFIGURATION AND TESTINGDial StringThis is the character string used to dial the other unit.Init StringThis is the character string use

Strany 40 - Port Configuration Screen

Configuration Screens 4-23Element ID HH:MM:SS MM/DD/YY <CR> <LF>NET Alarms: alarms <CR> <LF>DTE Alarms: alarms <CR&g

Strany 41 - 4-19

4-24 TERMINAL CONFIGURATION AND TESTINGSummaryThe Summary screen (Figure 4-12) is a display-only screen that summarizes all theconfiguration switch se

Strany 42 - Dial Backup Parameters Screen

Utilities 4-25UtilitiesThe Utilities screen (Figure 4-13) handles the functions described in the following paragraphs. Set Time The current time

Strany 43 - Configuration Screens

4-26 TERMINAL CONFIGURATION AND TESTINGMaintenanceResetThis field clears all user-selectable parameters, performance registers, passwords, and alarms

Strany 44 - Management Ports Screen

AFLASH PROM DOWNLOAD PROCEDUREThis appendix is a step-by-step procedure for downloading the Flash PROM software for the PRISM 3002.RequiredEquipment T

Strany 45

vTable of ContentsCopyright Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iiTrademarks . . . . . . . . . . . . . . . . . . . . .

Strany 46 - Summary Screen

A-2 FLASH PROM DOWNLOAD PROCEDURE7 Select the baud rate for configuring the communication program. The valid choices for the 3002 are 19200, 38400, an

Strany 47 - Utilities

PC Setup A-314Select the Download option and press ENTER for the download process to begin. The actual downloading procedure overwrites the exis

Strany 48

A-4 FLASH PROM DOWNLOAD PROCEDURE

Strany 49 - ROCEDURE

viBERT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-13Pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-13

Strany 50 - LASH PROM DOWNLOAD PROCEDURE

1GENERALIntroductionThe Verilink PRISM 3002 is a modular, single port, fractional T1 CSU/DSU designed to take advantage of T1 integrated access and pr

Strany 51

1-2 GENERALAn innovative design eliminates clocking problems on the high-speed data ports. The unit uses Flash memory allowing firmware upgrades in th

Strany 52

Specifications 1-3SpecificationsNetworkInterfaceLine Rate: 1.544 Mbps (± 50 ppm) Line Framing: D4 or ESF Line Code: AMI or B8ZS Input Signal: 0

Komentáře k této Příručce

Žádné komentáře