Configuring and Installing the Centum Series
3-10
Access System Centum Series User Manual
Steps 13 through 19 apply to Serial Port #1 while the identical Steps20
through 26 apply to Serial Port #2.
13. Serial Port #1 Data Rate.
[20. Serial Port #2 Data Rate]
In an Integrated Access, Fractional T1 environment, this selection MUST
be coordinated with the network supplier.
Before entering a value, the user must first determine if each DS0
will carry 56 kbps or 64 kbps user data and must then determine the
correct quantity of DS0s necessary to achieve the desired data rate.
See Density (item #8, above). If the NI is Clear, the 56/64 decision
is completely user optional and 64Kbps is recommended to obtain
maximum data transfer efficiency in the network.
NOTE
Main Menu HH:MM
_Configuration
M
ain Menu,
/
DOWN to
display:
Configuration
_Serial Port #1 (or 2)
LECT and
U
P/DOWN
t
o display:
Serial Port #1 (or 2)
_XXXK (XDS0)
S
ELECT to
display:
NOTE
Zobrazit stránku 33