Configuration Using the DIP Switches
06/17/97
C100 and C150 T1/FT1 CSU/DSU
3-15
Programming the DS-0s and DSX-1s (C100 and C150)
Switch packs 5, 6, and 7 settings are required for both the C100 and
C150.
DS-O assignment
Switch packs 5, 6 and 7 are used to determine whether a DS-0 is give
to the Synchronous Channel or the DSX-1. There are twenty-four DS-0s
in a T-1 frame and these DS-0s may be assigned to the Channel or DSX-
1 on a contiguous or non-contiguous basis.
If the switch position is Off (rocker arm down towards the front panel),
the DS-0 is not used or assigned to the DSX-1, depending on whether
the unit is a C100 or C150.
If the switch position is On, the DS-0 is assigned to the Synchronous
Channel. Even when the DSX1 interface is disabled, this selection must
be made in order to determine how many DS-0s go to the Synchronous
Channel
The programming of the DS-0s must match the DS-0 selection in the
remote unit when they are used on a point-to-point connection or they
must match the DS-0 selection on the Fractional T-1 facility provided
by the T-1 Carrier supplier.
Table 3-6 Switch pack-5: C100/C150 DS0-01 through DS0-08 and C150 DSX1-01 through DSX1-08
12345678 C100 Setting C150 Setting
Off-------DS0-01 not usedDSX1-1
On------- DS0-01 to Channel
Off -----DS0-02 not usedDSX1-2
On ----- DS0-02 to Channel
-Off ----DS0-03 not usedDSX1-3
-On ---- DS0-03 to Channel
--Off ---DS0-04 not usedDSX1-4
- - On - - - DS0-04 to Channel
---Off --DS0-05 not usedDSX1-5
---On -- DS0-05 to Channel
----Off -DS0-06 not usedDSX1-6
----On - DS0-06 to Channel
-----Off DS0-07 not used DSX1-7
-----On DS0-07 to Channel
------OffDS0-08 not used DSX1-8
------On DS0-08 to Channel
Off Off Off Off Off Off Off Off Factory default setting