DCSU 2911 E1 Craft Interface
4-14
Verilink DCSU 2911 User Manual
Net Port Alarm
Threshold Status
Submenu
Enter
T
from the
Performance/Status Menu
to access the
Net Port
Alarm Threshold Status Menu
. This menu shows the threshold
intervals set in the
Net Port Alarm Threshold Configuration Menu
which can be obtained by typing the command
A
from the
Main
Menu
.
It also displays the counts for each type of alarm. When the alarm
count exceeds its threshold value set in the
Net Port Alarm
Threshold Configuration Menu
, a (
Y
) displays after the count.
Figure 4-11 DCSU 2911 Net Port Alarm Threshold Status Menu
Net Port Alarm
Menu
Display the
Net Port Alarm Menu
by typing the command
A
from
the
Main Menu
. (Figure 4-1)
The
Net Port Alarm
Menu
contains a list of commands that bring
up additional alarm-related submenus. (Figure 4-12)
Cn Loss of Frame (LOF) Seconds: An LOF alarm is declared when a 3-second interval of
continuous Out of Frame (OOF) or Loss of Signal (LOS) state is detected. If at least 10
seconds elapse without an LOS or LOF error, the LOF alarm is cleared.
On Out-of-Frame (OOF) Seconds: A condition when any three of four consecutive frame bits
received from the E1 line are incorrect.
Rn Reset Registers: Use this option to clear out all counts and reset all registers to zero for a
particular port.
X Exit the 24 hour Performance Data screen
Table 4-7 Performance/Status Parameters
Command Description
-- DCSU 2911 NET PORT ALARM THRESHOLD STATUS MENU --
PORT 1 PORT 2 PORT 3 PORT 4
LOF counts(exceeded) 0(N) 0(N) 0(N) 0(N)
interval 3 0 0 0
LOS counts(exceeded) 0(N) 0(N) 0(N) 0(N)
interval 3 0 0 0
RAI counts(exceeded) 0(N) 0(N) 0(N) 0(N)
interval 1 0 0 0
AIS counts(exceeded) 0(N) 0(N) 0(N) 0(N)
interval 1 0 0 0
BPV counts(exceeded) 0(N) 0(N) 0(N) 0(N)
interval 1 0 0 0
ES 15min counts(exceeded) 0(N) 0(N) 0(N) 0(N)
ES 24hr counts(exceeded) 0(N) 0(N) 0(N) 0(N)
SES 15min counts(exceeded) 0(N) 0(N) 0(N) 0(N)
SES 24hr counts(exceeded) 0(N) 0(N) 0(N) 0(N)
X) exit this screen
[1,1] DCSU 2911 >