6 CHAPTER 2: INSTALLATION AND CONFIGURATION
Supplied
Materials
The Multi-Rate DDS CSU/DSU is shipped from the factory
with the following standard equipment.
external AC power supply
reference manual
adhesive strip
phone cable
Wallmount
Installation
Using Adhesive Strips
1 Select a place close to a 115 VAC outlet with clearance for the
signal and power cables. The indicators and switches should be
easily accessible.
2 Verify the mounting surface is clean.
3 Cut the adhesive strip to the desired length and affix the backing
of one piece to the underside of the unit.
4 Attach the other adhesive strip to the piece on the underside of
the unit.
5 Remove the backing to expose the sticky surface.
6 Press the underside of the unit firmly against the selected place.
Using Screws
1 Select a place close to a 115 VAC outlet with clearance for the
signal and power cables. The indicators and switches should be
easily accessible.
2 Vertically place two #6 screws 3-1332 inches apart at the
selected place. Leave the screws out about an eighth of an inch.
3 Place the upright unit over the screws until the holes engage and
slide the unit down until it locks.
Connections The Multi-Rate DDS CSU/DSU has three interface connectors:
an RJ-48C DDS network connector, a 3-pin power connector,
and an RS-232 connector.
DDS
Network
Connection
The network DDS facility
interface is a standard
RJ-48C (8-pin) modular
jack with the following
pinout.
Table 2-1 DDS Network Connection
Pin Assignment
1 Network Transmit Out
2 Network Transmit Out
36 Not Used
7 Network Data In
8 Network Data In