Overview
1-4 Verilink IMUX User Manual
Table 1-2 Rear Connector Modules for IMUX
Figure 1-2 IMUX Front Panel with DIM Rear Panels
IMUX Compliancy
Standards
The IMUX module complies with the following ITU-T, ANSI, ISO, and
Bellcore standards and requirements:
•
ANSI T1.107.1988 and 107a.1990
•
AT&T Publication 54014
•
AT&T Publication 54024
•
FCC Part 15
•
ISO 9000
Regulatory
Requirements
This product complies with the following regulatory specifications
as they apply to telecommunications equipment:
•
FCC—Part 15, Subpart J, Class A: Computing Devices
•
15.810: Radiated Emission
•
15.812: Conducted Emission
•
UL 1459, 2nd Edition
•
CSA—C225
DIM Interface Modules for IMUX
Module Electrical
Interface
Physical Interface Bandwidth Capacity
DIM 3664
HSSI 50-pin Amplimite 16 Mbit/s (8 T1s)
DIM 3634
V.35 34-pin Winchester 10 Mbit/s (6 T1s)
IMUX
DATA
STAT
NET
INPUT
EXT TIMING
HSSI
DIM
3664
V.35
DIM
3634
INPUT
EXT TIMING