Verilink SCC 2020 User ManualOctober 1999P/N 880-503268-001-B1SCC2020NETSTATEQPTCRAFTFUNCTIONEQPT57EXEINOUTINOUTNETEQPTNETMON
Overview1-2Verilink SCC 2020 User ManualThe SCC modules are compatible with HP OpenView™ and other SNMP network management applications.Other Features
OverviewVerilink SCC 2020 User Manual1-3Compatible ModulesTypes of application modules which may be managed by the SCC 2020 are illustrated below:Tabl
Overview1-4Verilink SCC 2020 User ManualFront and Back ModulesThis section describes the SCC 2020 front module and the rear connector interface module
OverviewVerilink SCC 2020 User Manual1-5CIMs for SCC 2020SCC Node Controller front module must be installed with a rear connector module which provide
Overview1-6Verilink SCC 2020 User Manual
Verilink SCC 2020 User Manual2-1Chapter2Quick Set-UpThis section details a quick, step-by-step procedure for configuring the SCC 2020. For the purpose
Quick Set-Up2-2Verilink SCC 2020 User ManualFigure 2-1 SCC 2020 Main Menu CSU ConfigurationWhen installing an SCC 2020 or TAC 2010 module which is t
Quick Set-UpVerilink SCC 2020 User Manual2-3Figure 2-2 SCC 2020 Configuration Menu The factory default values for the SCC 2020 are shown. The unit
Quick Set-Up2-4Verilink SCC 2020 User Manualinvolved. When the carrier provides a timing signal, all other devices on the T1 must use that signal to d
Quick Set-UpVerilink SCC 2020 User Manual2-5Figure 2-3 DIU 2130 Configuration Menu NOTE:For the remainder of this chapter you will not be instructed
iiVerilink SCC 2020 User ManualCopyright NoticeCopyright 1999 Verilink Corporation. All rights reserved.This document does not create any express or
Quick Set-Up2-6Verilink SCC 2020 User ManualNow type “D2”, the prompt enter port 2 channels >enter port 2 channels >enter port 2 channels >en
Quick Set-UpVerilink SCC 2020 User Manual2-7For more information on DIU 2130 modules see the DIU 2130 User Manual.The configuration of the SCC 2020 is
Quick Set-Up2-8Verilink SCC 2020 User Manual
Verilink SCC 2020 User Manual3-1Chapter3ConfigurationThis chapter covers configuring the CSU portion of the SCC 2020 Node Controller, setting up the S
Configuration3-2Verilink SCC 2020 User ManualVerilink provides a cable called a "Craft cable" which has an RJ-11 modular connector at one en
ConfigurationVerilink SCC 2020 User Manual3-3Figure 3-1 SCC 2020 Main Menu From this menu you may navigate from card to card, or choose various opti
Configuration3-4Verilink SCC 2020 User ManualTable 3-3 SCC 2020 Main Menu CommandsThe Configuration MenuIn the Main Menu shown in Figure 3-1, the elem
ConfigurationVerilink SCC 2020 User Manual3-5Figure 3-2 CSU Configuration Menu Configuration Menu CommandsSome of the commands on the CSU Configurat
Configuration3-6Verilink SCC 2020 User ManualTable 3-4 CSU Configuration OptionsMenu Option Description InstructionsW) framing Selects T1 framing mode
ConfigurationVerilink SCC 2020 User Manual3-7M) distance Cable length option, used to increase DSX-1 signal strength when DSX-1 cable is long. Choices
Verilink SCC 2020 User Manualiii • If the telephone company alters its equipment in a manner that can affect the use of this device, it must give you
Configuration3-8Verilink SCC 2020 User ManualC1-C5) canned configAllows selection of any of five complete configurations which all use CSU mode (no DI
ConfigurationVerilink SCC 2020 User Manual3-9ModeThe CSU portion of an SCC 2020, (a TAC 2010 CSU), has three distinctly different modes of operation.
Configuration3-10Verilink SCC 2020 User ManualDrop And InsertModeDrop and Insert mode combines the features of CSU mode and Mux mode. The DSX-1 equipm
ConfigurationVerilink SCC 2020 User Manual3-11Figure 3-4 Node Administration Menu If any changes are made to the Ethernet or SLIP configurations, th
Configuration3-12Verilink SCC 2020 User ManualN) site name Sets an alpha-numeric identifier used to tell one node from another.Site Name: Tech Pubs
ConfigurationVerilink SCC 2020 User Manual3-13Modem ConfigurationWhen M is selected on the SCC 2020 Node Administration Menu, the Modem Configuration
Configuration3-14Verilink SCC 2020 User ManualFigure 3-5 Modem Configuration Menu ModemConfigurationOptionsThe Modem Configuration Menu is used to s
ConfigurationVerilink SCC 2020 User Manual3-15Table 3-6 Modem Configuration CommandsMenu Option Description InstructionsD) Answer Toggles answer mode
Configuration3-16Verilink SCC 2020 User ManualFar-End ManagementYou may be able to access the SCC module in a far-end node and, through it, option any
ConfigurationVerilink SCC 2020 User Manual3-17Far-End ProcedureTo access the node at the far end, follow these steps:1. Login to the Craft interface
ivVerilink SCC 2020 User ManualDeutschVORSICHT!Explosionsgefahr bei unsachgemäßem Ersetzen der Batterie! Batterie gleichen Typs und gleicher Qualität
Configuration3-18Verilink SCC 2020 User ManualFirmware Upgrade ProceduresFirmware upgrades performed using an SCC 2020 may be divided into two categor
ConfigurationVerilink SCC 2020 User Manual3-19OverviewSCC firmware can be upgraded by using FTP to transfer the new executable files into the card.
Configuration3-20Verilink SCC 2020 User ManualNOTE:The boot command reboots only the SNMP and Craft interface functions of the SCC 2020, any user data
ConfigurationVerilink SCC 2020 User Manual3-21Upgrading Flashbank BUse this procedure to upgrade flashbank B only if one of the following is true:• Fl
Configuration3-22Verilink SCC 2020 User Manual9. Record the file size of the FLASH.B file.10. Issue the command “binary”.NOTE:If you fail to issue the
ConfigurationVerilink SCC 2020 User Manual3-231. Place the download file received from Verilink in a known path on an FTP server.2. Connect to the SCC
Configuration3-24Verilink SCC 2020 User Manualrouted through a Digital Access and Crossconnect System (DACS) and the FDL will be terminated at the DAC
ConfigurationVerilink SCC 2020 User Manual3-25Thumbwheel ProcedureA four-step procedure is used for each thumbwheel command:1. Set the thumbwheel to t
Configuration3-26Verilink SCC 2020 User Manual41 SCC 2020 TAC 2010Canned configuration #2, EQPT=ESF/AMI NET=ESF/AMI42 SCC 2020 TAC 2010Canned confi
ConfigurationVerilink SCC 2020 User Manual3-2758 SCC 2020 TAC 2010 DIU 2140Set data bus to C (Mux mode)59 SCC 2020 TAC 2010 TAC 2130Send in-
Verilink SCC 2020 User Manualv • This product should be operated only from the type of power source indicated on the marking label and manual. If you
Configuration3-28Verilink SCC 2020 User Manual87 TAC 2130 DIU 2130Canned configuration #7, assigns timeslots 1-23 to data port #1 and timeslot 24 to d
Verilink SCC 2020 User Manual4-1Chapter4Performance MonitoringOnce the SCC 2020 is installed, the performance monitoring routines allow you to monitor
Performance Monitoring4-2Verilink SCC 2020 User ManualDefinitionsThe acronyms shown on the Performance Monitoring Menu are described in Table 4-1 bel
Performance MonitoringVerilink SCC 2020 User Manual 4-324-hour Errored SecondsThe 24-hour Errored Seconds selection on the Performance Monitoring Menu
Performance Monitoring4-4Verilink SCC 2020 User Manual24-Hour Bursty Errored SecondsBursty Errored Seconds are more severe than errored seconds and ma
Performance MonitoringVerilink SCC 2020 User Manual 4-524-Hour Severely Errored SecondsSeverely Errored Seconds pose a serious threat to the integrity
Performance Monitoring4-6Verilink SCC 2020 User Manual24-Hour Unavailable SecondsAfter ten Severely Errored Seconds in a row, the CSU begins to count
Performance MonitoringVerilink SCC 2020 User Manual 4-724-Hour Loss of Frame CountA loss of frame synchronization on a T1 circuit causes a loss of all
Performance Monitoring4-8Verilink SCC 2020 User Manual
Verilink SCC 2020 User Manual5-1Chapter5DiagnosticsWhile installing your SCC 2020, or after it has been placed into service, the Diagnostic routines a
viVerilink SCC 2020 User Manual
Diagnostics5-2Verilink SCC 2020 User ManualDiagnostics MenuA sample of the Diagnostics Menu is shown below in Figure 5-1.In this example, the word PUL
DiagnosticsVerilink SCC 2020 User Manual 5-3Figure 5-2 Diagnostics Menu Status MessagesThe status messages which may appear on the Diagnostics Menu
Diagnostics5-4Verilink SCC 2020 User ManualDiagnostic CommandsThere are seventeen command options available on the SCC 2020 diagnostics menu. Table 5
DiagnosticsVerilink SCC 2020 User Manual 5-53) 1 in 8 Starts 1 in 8 test CSU transmits a 1 in 8 pattern, which guarantees one bit of every 8 will be a
Diagnostics5-6Verilink SCC 2020 User ManualFront Panel LEDsThis section describes the function of the SCC 2020 LED indicators.EQPT LEDThe EQPT (equipm
DiagnosticsVerilink SCC 2020 User Manual 5-7STAT LEDThe STAT (CSU status) LED is a three-color indicator with six possible states, as follows: Table 5
Diagnostics5-8Verilink SCC 2020 User ManualTest ProceduresTesting may generally be divided into two categories, tests which are conducted to verify an
DiagnosticsVerilink SCC 2020 User Manual 5-9Figure 5-4 Sending And Receiving PatternIf the QRSS pattern is received with no errors, the Test Error Cou
Diagnostics5-10Verilink SCC 2020 User ManualTroubleshootingWhen it is known that a problem exists in a T1 network application, a different approach is
DiagnosticsVerilink SCC 2020 User Manual 5-11Table 5-6 Troubleshooting TipsTrouble SuggestionSignal loss — verify that a T1 circuit is connected to th
Table of ContentsVerilink SCC 2020 User Manual viiOverview ...
Diagnostics5-12Verilink SCC 2020 User ManualLoopback PlugFor a completely reliable test of a CSU, make a T1 loopback plug and plug it in to the networ
DiagnosticsVerilink SCC 2020 User Manual 5-13With a loopback plug in the network port, any customer equipment connected to the SCC 2020 (or a data por
Diagnostics5-14Verilink SCC 2020 User ManualFigure 5-5 T1 Loopback Plug123456781524
IndexVerilink SCC 2020 User Manual Index-1Numerics1 in 8 test 5-51.544 MHz clock 3-824 Hour Bursty Errored Seconds 4-424 hour Errored Seconds 4-324
Index-2 Verilink SCC 2020 User Manual EXT CLK LOSS 5-3EXT TTL 3-8external clock 3-8Ffar element 3-4Far End Loop 5-8far end polling 3-9Far-End Main Men
Verilink SCC 2020 User Manual Index-3SNMP managers 3-13ST vs INV-ST 5-12Status Messages 5-3Subnet Mask 3-12TT1 CSU 3-4T1 framing 3-6T1 loopback plug
Index-4 Verilink SCC 2020 User Manual
VERILINK CORPORATION127 JETPLEX CIRCLE, MADISON, ALABAMA 35758TEL: (800) 837-4546October 1999P/N 880-503268-001-B1
viii Verilink SCC 2020 User Manual 24-hour Errored Seconds ...... 4-324-Hour Bursty
Verilink SCC 2020 User Manual1-1Chapter1OverviewThis User Manual describes the SCC 2020 Node Controller module, a component of Verilink’s Access Syste