VT100 Interface 4-19
Parity
Sets the parity bit.
Values: None, Odd, Even
Default: None
Stop Bit
Selects the number of bits required to end the character.
Values: 1, 2
Default: 1
DTR Alarm Control
Choices for DTR Alarm Control are Enable” and “Disable”; the default
setting is “Disable.” Setting DTR Alarm Control to “Enable” allows the unit
to go into alarm on a loss of DTR, which occurs when the Serial port detects
that the DTR signal is low.
Values: Enable, Disable
Default: Disable
DTR Alarm Status
Lets you view the current DTR Alarm status.
Diagnostic Messages
Enables the Supervisory port to send out diagnostic messages upon power-up.
Values: Enable, Disable
Default: Enable
NOTICE: When in SCADA mode, these diagnostic messages disrupt the connected
device. Therefore, if using the SCADA mode, set this value to
“Disable.”
Current Pin Status
The Current Pin Status, which shows the state of the RS-232 pins, is also
displayed on the Supervisory interface screen.
Service Table Screen
The Service Table screen (Figure 4.15) provides a view of the unit’s defined
services and displays the Interface, Type, Pair, and Status parameters for each
service.