Verilink WANsuite 5165 (34-00301.H) Product Manual Uživatelský manuál Strana 162

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 235
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 161
4-38 WANsuite 5165
To change the Username and Secret for a selected CHAP Index, enter the new
information in the appropriate field(s) and press the “Esc” key.
SCADA Service Details Screen
NOTICE: SCADA traffic has a higher priority than other types of traffic flowing
through the unit. Refer to Normal Tx Queue Size on page 4-30 for more
details.
The SCADA Service Details screen (Figure 4.31) lets you access and read or
change the parameters described in the paragraphs listed below.
Figure 4.31
SCADA Service Details Screen
Message Size
Maximum number of characters to buffer before sending a frame.
Values: 01024
Default: 256
Idle Character Delay
Maximum number of idle character time to wait before sending a frame.
Values: 065535
Default: 10
Input Terminator
Decimal value of the character that terminates a message before sending a
frame.
Values: 0255
Default: 0
Data Direction
Data direction that the port will support. If set to “Input,” the port will only
accept incoming data and will not transmit data. If set to “Output,” the port
will ignore any incoming data. If set to “Both,” the port will process all data.
Values: Input, Output, Both
Default: Both
Zobrazit stránku 161
1 2 ... 157 158 159 160 161 162 163 164 165 166 167 ... 234 235

Komentáře k této Příručce

Žádné komentáře