3-14 WANsuite 5650
This field configures the threshold for the number of Loss of Sync Word
(LOSW) Seconds within any given 15-minute performance data collection
interval. If the value of LOSW in a particular 15-minute collection interval
reaches/exceeds this value, a trap will be generated. One trap will be sent per
This field configures the threshold for the number of unavailable seconds
(UAS) within any given 15-minute performance data collection interval. If
the value of UAS in a particular 15-minute collection interval reaches/exceeds
this value, a trap will be generated. One trap will be sent per interval per
Span Endpoints Screen
Selecting the “Span Endpoints” field on the SHDSL screen will display the
screen seen in Figure 3.11. The Span Endpoints screen displays each unit of
the span. User-selectable prompts are provided to view the Span Endpoint
Details (page 3-14), Span Endpoint Maintenance (page 3-16), Alarm Profiles
(page 3-12), and Span Endpoint Performance (page 3-17) screens. If the
SHDSL link is not up, only the local side of the span will be displayed.
Moving the cursor to an entry in the Unit column of this screen and pressing
the “Enter” key will display the span endpoint details for that unit. (See
Span
Endpoint Details Screen
Figure 3.11
Span Endpoints Screen
Span Endpoint Details Screen
The Span Endpoint Details screen (Figure 3.12) is accessed by moving the
cursor to a Unit identifier in the Span Endpoints screen and pressing the
“Enter” key. This screen supports retrieval of unit inventory information
available via the EOC from units in a SHDSL line.