Legacy Host Options
183
H - Send
Disconnect
Message
When this option is set, the MultiPro unit sends the message defined in the
disconnect message field of the line module screen to the host when the station
goes off-line as shown in Figure 10-32. This is primarily used in dial-up
applications where the network administrator wants to make sure that each user is
logged off when they disconnect from the dial modem. This message would most
likely contain a log-off command so that the next user to dial in does not end up
with the previous users authority or in a program that may contain sensitive
information.
TXPORT INTELLINET Configuration Program
Configuration 1000
Host Port Station Parameters
Line Module [1 ] Port [1] Description
Host Group Auto Connect Options XN #
Address Address Station Name ABCDEFGHIJKLMNOP Type
G1 NNNYNNYNNNNNNNNN N
FT NNNNNNNNNNNNNNNN N
F1=Hlp F2=Mod F3=Add F4=List F5=Clr F6=DelAll F7=Copy F8=Jmp F9=Prev F10=Next
Figure 10-31
HOSTB Port Connection
DOWNLOAD CONFIG
MODE BACKUP NET ALARM POWER
PRISM 9111
TRANSPORT
®
Disconnect Message
Processor
Modem
X
Figure 10-32
Typical Send Disconnect Message Application