10 CHAPTER 1: GENERAL
Line Impedance: balanced 100 Ω (± 5%)
Input Signal: DS1, +1 to -27 dB (ALBO)
Output Signal: 3.0 V (±15%) base-peak into 100 Ω
Line Build Out: 0, -7.5, -15, and -22.5 dB attenuation
Line Protection: 1000 V lightning, input and output
Jitter Control: per TR62411 and T1.403
Pulse Density: per TR62411
Industry Standards.
FCC Compliance: Part 15 Subpart B, Class A, Part 68
U.S. Safety: 1950 3
rd
Edition
Canadian Safety: C22.2 No. 950-95
IC: CS-03, Issue 8
ANSI T1.403: 1989
TR54016: April 1988
TR62411: December 1990
LAN Interface
Connection: 10 Base-T, RJ-48
Ethernet: ISO/IEC 802-3
Protocols
IBM: SNA/SDLC, SNA/RJE, 3780 BSC, 3270 BSC, 5250,
NCR: Poll/Select, UNIX X.25
Unisys: Poll/Select, T27 emulation, Uniscope
TTY: Host, Terminal, Printer
The protocol suite supported must be specified when ordering.
Logical Addresses
Supported: 512 (9101, 9111, and 9211) 1500 (6400 and 6800)
IP Routing Protocols: IP, RIP, RIP-II, and OSPF
IPX Routing
Protocols: IPX, RIP, SAP, and NLSP
LAN Protocols: Novell IPX, TCP/IP, NetBios, DECNet, XNS,
Banyan VINES, AppleTalk
WAN Protocols: Frame Relay, X.25, Full-Duplex Multi-Drop, IP PAD
WAN Media: Analog and digital leased lines, dial lines, Switched 56,
ISDN, microwave links, satellite links
Filtering: Station filtering and protocol filtering
Bridging Protocols: Transparent bridging with full IEEE 802.1d support