Configuration Options for AS2000 and ConnecT1 Plus
Access Manager 2000 User Manual
5
-
97
timing and probably requires some trial and error. First, choose ST and
check the end-to-end data transmission on the data port. If transmission
does not work properly, choose INVERT S .
EQP Handshaking
The DIU 2130 and DIU 1130 supports five handshaking signals on each
data port. The V.35 names appear in the DIU menu screen, although
RS449 and RS530 interfaces are also available. Set each signal to N or Y.
The DIU 2130 and data port handshaking signals are listed below.
Table 5-12 DIU 2130 and Data Port Handshaking Signals
Loss of Signal
Select from one of the following options:
NO Do not
generate a Loss of Signal signal.
RTS Generate an LOS alarm when RTS is missing.
DTR Generate an LOS alarm when DTR is missing.
Handshaking Signals
Circuit
Direction
EQP Handshaking Options
V.3 5
(screen)
RS449 RS530 N (default) Y
RTS RS CA to DIU signal from data equipment forced on (asserted)
DTR TR CD to DIU signal from data equipment forced on (asserted)
CTS CS CB from DIU follow conditioned RTS from
data equip.
(Note 1
forced on (asserted)
DSR DM CC from DIU follow conditioned DTR from
data equip. (Note 2)
forced on (asserted)
RLSD
(DCD)
RR CF from DIU on
(Note 3)
forced on (asserted)
NOTE 1. (CTS) Set this option to
NO
(default) if you want CTS from the DIU to follow conditioned RTS from the data
equipment. If
NO
, CTS turns off automatically if the associated NCC, CCC, or TAC goes into an LOF state or receives a
Yellow (i.e., RAI) alarm regardless of RTS. Or, set this option to
YES
to permanently turn on DSR.
NOTE 2. (DSR) Set this option to
NO
(default) if you want DSR from the DIU to follow conditioned DTR from the data
equipment. If
NO
, DSR turns off automatically if the associated NCC, CCC, or TAC goes into an LOF state or receives
a Yellow alarm regardless of DTR. Or, set this option to
YES
to permanently turn DSR on.
NOTE 3. (RLSD) Set this option to
NO
(default) if you want RLSD on except when the associated NCC, CCC, or TAC
goes into an LOF state. Or, set the RLSD t
YES
to permanently turn it on.