Strany 1 - ConnecT 56K DSU User Manual

Access System 2000ConnecT 56K DSU User ManualVerilink Corporation145 Baytech DriveSan Jose, California 95134Part Number 896-502110-001-ANovember 1993

Strany 2

List of Tables viii ConnecT 56K DSU User ManualTable 3-29 RDL Select Commands ...

Strany 3 - Table of Contents

ConnecT 56K DSU User Manual 1-1Chapter1 IntroductionThis chapter provides an overview of the Verilink ConnecT 56K DSU, Digital Data Service (DDS), an

Strany 4

Introduction1-2 ConnecT 56K DSU User ManualFigure 1-1 ConnecT 56K DSU Front ViewTable 1-1 LED IdentificationThe rear panel contains three data DTE c

Strany 5

Unit OverviewConnecT 56K DSU User Manual1-3Table 1-2 Identification of NumbersItem Function 1. Auxiliary EIA-232 Secondary channel services 2. Power

Strany 6 - ConnecT 56K DSU User Manual

Introduction1-4 ConnecT 56K DSU User ManualDDS OverviewDigital Data Service (DDS) is a nationwide service that allows interconnection and transport of

Strany 7 - List of Figures

Switched 56 overviewConnecT 56K DSU User Manual1-5Switched 56 overviewThis dial-up 4-wire Digital Data Service allows customers to pay for data connec

Strany 8

Introduction1-6 ConnecT 56K DSU User Manual

Strany 9 - List of Tables

ConnecT 56K DS User Manual 2-1Chapter2 InstallationThis chapter explains how to install the ConnecT 56K DSU.Unpack, inspect, power up Carefully inspe

Strany 10

Installation2-2 ConnecT 56K DSU User ManualCAUTIONPower to the DSU must be from a 115 VAC, 60Hz that is grounded.!

Strany 11 - 1 Introduction

Connecting the cables ConnecT 56K DS User Manual2-3Connecting the cableThis section describes the following connections: Network interface connection

Strany 12 - ConnecT 56K DSU

Important NoticeBefore performing any operations, PLEASE READ AND UNDERSTAND ALL INSTRUCTIONS IN THIS MANUAL. WHEN YOU ARE FINISHED, PUT THIS MANUAL I

Strany 13 - Unit Overview

Installation2-4 ConnecT 56K DSU User Manualprimary DTE rate is configured from the front panel. The PRIMARY Data Terminal Equipment can operate in asy

Strany 14 - DDS Overview

Connecting the cables ConnecT 56K DS User Manual2-5Table 2-3 Pin Assignments for Primary V.35 ConnectorPin CCITT DescriptionA 101 Protective Ground (

Strany 15 - Switched 56 overview

Installation2-6 ConnecT 56K DSU User ManualIf used, the secondary data terminal equipment should be connected to the Auxiliary EIA 232 connector. The

Strany 16 - Introduction

Configuration ConnecT 56K DS User Manual2-7ConfigurationThe ConnecT 56K DSU contains four different user profiles (sets of configurations options) lis

Strany 17 - 2 Installation

Installation2-8 ConnecT 56K DSU User ManualConfiguration methodsThe ConnecT 56K DSU provides four different methods for local configuration and three

Strany 18 - Installation

Configuration methods ConnecT 56K DS User Manual2-9Once the command mode is entered, AT commands can be transmitted to the ConnecT 56K DSU to configur

Strany 19 - Connecting the cable

Installation2-10 ConnecT 56K DSU User Manual[F][A][C][V.25 bis COMMAND][FCS][F] The address field [A] is FFH. The control field [C] is set to 13H exce

Strany 20

Configuration methods ConnecT 56K DS User Manual2-11Command descriptions The Verilink V.25 bis command set is a subset of the CCITT V.25 bis command s

Strany 21 - Connecting the cables

Installation2-12 ConnecT 56K DSU User ManualIf verbose responses are disabled (ATV0), the 3 character responses listed below are the only ones returne

Strany 22 - Secondary

Configuration methods ConnecT 56K DS User Manual2-13The remote password may or may not be required depending on the present configuration of the remot

Strany 23 - Configuration

Table of ContentsConnecT 56K DSU User Manual iCHAPTER 1 - Introduction ...

Strany 24 - Configuration methods

Installation2-14 ConnecT 56K DSU User ManualIf this command is entered with no parameters, the INVPS response is returned. If no register number is in

Strany 25 - V.25 bis

ConnecT 56K DS User Manual 3-1Chapter3 OperationThis chapter describes the keypad, menu functions, and ConnecT 56K DSU operation.Understanding the ke

Strany 26

Operation3-2 ConnecT 56K DSU User ManualTable 3-2 LED IdentificationThis section explains the use of buttons and manual operation. Enter button The E

Strany 27 - ConnecT 56K DS User Manual

Understanding the keypad ConnecT 56K DS User Manual3-3Note:The active menu item or configuration parameter flashes. Examples: 1. To view submenu items

Strany 28

Operation3-4 ConnecT 56K DSU User Manualthe desired letter. If the letter is mistakenly pressed without using the * key, the numbered item will become

Strany 29 - Switched 56

Menu structure ConnecT 56K DS User Manual3-5Menu structureThe ConnecT 56K DSU uses a multilevel menu approach to access its many features. All menu op

Strany 30

Operation3-6 ConnecT 56K DSU User Manual4=Dial Provides manual dialing functions. This menu item is displayed and available for use only when the Accu

Strany 31 - 3 Operation

General operations and menus ConnecT 56K DS User Manual3-7General operations and menusThis section discusses general operations and menus for the Conn

Strany 32 - Manual operation

Operation3-8 ConnecT 56K DSU User ManualFrom the opening Main Menu 1= STATUS 2=TEST 3= CONFIG 4=DIAL press the number 3 to activate (begin flashing) 3

Strany 33 - Examples

1 = STATUS ConnecT 56K DS User Manual3-91 = STATUSThe Status Selection displays two lines at a time of the current operational status of the network a

Strany 34

ii ConnecT 56K DSU User Manual* (Shift) ... 3-3 (Q

Strany 35 - Menu structure

Operation3-10 ConnecT 56K DSU User ManualTo view additional information, press the Up or Down scroll key which displays two new lines of information.

Strany 36

2 = TEST ConnecT 56K DS User Manual3-112 = TESTThe ConnecT 56K DSU is able to perform a variety of tests that allow problems to specific components of

Strany 37 - General operations and menus

Operation3-12 ConnecT 56K DSU User Manualeffected by using the up scroll button. At every level of the menu pressing the Cancel button will return to

Strany 38

2 = TEST ConnecT 56K DS User Manual3-13Operation Follow standard operating procedure. When 2=TEST is flashing: Press the Enter button resulting in the

Strany 39 - 1 = STATUS

Operation3-14 ConnecT 56K DSU User ManualTesting from the remote end of the circuit is normally done with a bit error rate tester (BERT) or, by using

Strany 40 - Cancel key

2 = TEST ConnecT 56K DS User Manual3-15To Exit a Test press the Quick # key to access the 1=EXIT TEST/2=DISPLAY STATUS submenu or press the Cancel key

Strany 41 - 2 = TEST

Operation3-16 ConnecT 56K DSU User ManualFigure 3-6 Status DisplayMenu map 2=TEST/1= LOCAL UNIT/2=LOOP ONLY (RT)/Displays Operation Follow standard o

Strany 42 - 1=Local Unit

2 = TEST ConnecT 56K DS User Manual3-17Figure 3-7 Status Display Menu map 2=TEST/1= LOCAL UNIT/3=DTE ONLY/Displays Operation Follow standard operatin

Strany 43

Operation3-18 ConnecT 56K DSU User ManualFigure 3-8 DTE WITH TP MENUMenu map 2=TEST/1= LOCAL UNIT/4=DTE WITH TP/Submenus 1-6/DisplaysOperation Follow

Strany 44

2 = TEST ConnecT 56K DS User Manual3-19While this test is being performed, the ConnecT 56K DSU displays: DTE WITH TP TEST ERR=XX The first line of the

Strany 45

ConnecT 56K DSU User Manual iiiSubmenu 8 CD options ... 3-38Submenu 9 TR Optio

Strany 46 - Figure 3-6 Status Display

Operation3-20 ConnecT 56K DSU User Manual1=2047 PATTERN 2= 511 PATTERN Continue with operational procedures described for DTE & Loop (LL).6 = Self

Strany 47 - Figure 3-7 Status Display

2 = TEST ConnecT 56K DS User Manual3-21Menu map 2=Test/2=Remote Unit/Selections Operation Follow standard operating procedures. When 2=Remote Unit is

Strany 48

Operation3-22 ConnecT 56K DSU User ManualStatus Displays Remote With TP TEST Err - 00 Table 3-8 Test Displays Table 3-9 Available interface leads 1

Strany 49

2 = TEST ConnecT 56K DS User Manual3-23Menu map 2=TEST/1=LOCAL UNIT or REMOTE UNIT/Tests/1=EXIT TEST or 2=DISPLAY STATUS Note:Shaded items are restric

Strany 50 - 2=Remote unit

Operation3-24 ConnecT 56K DSU User Manual3 = CONFIGThe Configuration menu consists of a group of five sub-menus relating to a specific interface or fu

Strany 51

3 = CONFIG ConnecT 56K DS User Manual3-25Figure 3-9 Complete Configuration MenuMenu flow is normally depicted from left to right. When scrolling thro

Strany 52

Operation3-26 ConnecT 56K DSU User ManualMenu map 3=CONFIG/1=LOCAL/1=NETWORK OPT. Operation Follow standard operating procedures. When 1=NETWORK OPT.

Strany 53

3 = CONFIG ConnecT 56K DS User Manual3-27Submenu 1 loop rate The LOOP RATE option sets the loop operating speed. The unit should be set to the rate re

Strany 54 - 3 = CONFIG

Operation3-28 ConnecT 56K DSU User ManualSubmenu 2 network A two digit decimal address can be assigned to each ConnecT 56K DSU. This addressing capabi

Strany 55 - 1=Network

3 = CONFIG ConnecT 56K DS User Manual3-29Table 3-15 Network Type Commands Submenu 5 clock source The Clock Source options specifies the timing source

Strany 56

iv ConnecT 56K DSU User Manual

Strany 57

Operation3-30 ConnecT 56K DSU User ManualMenu map 3=CONFIG/1=LOCAL/2=DTE OPT. Operation Follow standard operating procedures. When 2=DTE OPT. is flash

Strany 58

3 = CONFIG ConnecT 56K DS User Manual3-31Submenu 1 DTE rate The DTE RATE option sets the operating speed of the DTE interface when the unit is set for

Strany 59 - 2 = DTE options

Operation3-32 ConnecT 56K DSU User Manualconstraint can also be eliminated by selecting the SCRAMBLER ON option. For 64K clear channel operation, ther

Strany 60 - 2=Connector Type

3 = CONFIG ConnecT 56K DS User Manual3-33Submenu 3 data format The DATA FORMAT option is used to select either the synchronous or asynchronous mode of

Strany 61

Operation3-34 ConnecT 56K DSU User ManualSubmenu 4 DTE CMD option The DTE COMMAND option is used to enable the DTE interface for one of the three diff

Strany 62 - Not applicable

3 = CONFIG ConnecT 56K DS User Manual3-35Submenu 5 transmit clock The Transmit Clock option is used to select the source of the clock used to transfer

Strany 63

Operation3-36 ConnecT 56K DSU User ManualSubmenu 6 CS options The CS OPTIONS menu is used to select one of five different control modes for the Clear

Strany 64

3 = CONFIG ConnecT 56K DS User Manual3-37Specified times for the SHORT and LONG delays at the different operating speeds are:Submenu 7 anti -stream Th

Strany 65

Operation3-38 ConnecT 56K DSU User ManualContinue with standard operating procedures to select menu options. At the end of the options the system wilL

Strany 66

3 = CONFIG ConnecT 56K DS User Manual3-39Table 3-25 CD Options Commands Submenu 9 TR Options The TR OPTIONS menu is used to select the ConnecT 56K DS

Strany 67

List of FiguresConnecT 56K DSU User Manual vFigure 1-1 ConnecT 56K DSU Front View ...

Strany 68

Operation3-40 ConnecT 56K DSU User ManualSubmenu A SR options The SR Options menu is used to select the operating mode for the data set ready (SR) lea

Strany 69

3 = CONFIG ConnecT 56K DS User Manual3-41Menu map 3=CONFIG/1=Local/2=DTE Opt./B=Secondary Rate Operation To display the Secondary Rate submenu of 1=LO

Strany 70

Operation3-42 ConnecT 56K DSU User ManualMenu map 3=CONFIG/1=Local/3=Test Options Operation Follow standard operating procedures. When 3=TEST OPTIONS

Strany 71 - 3=Test options

3 = CONFIG ConnecT 56K DS User Manual3-43Table 3-29 RDL Select Commands Submenu 3 EIA LLB select The EIA LLB Select option is used to specify whether

Strany 72 - (0=OFF): 00SEC

Operation3-44 ConnecT 56K DSU User ManualMenu map 3=CONFIG/1=Local/4=Dial Options Operation Follow standard operating procedures. When 4=Dial Options

Strany 73 - 4 = Dial options

3 = CONFIG ConnecT 56K DS User Manual3-45The Manual Command option is a short cut method for entering configuration and control commands for the Conne

Strany 74

Operation3-46 ConnecT 56K DSU User Manual

Strany 75 - 5 = Manual

ConnecT 56K DSU User Manual A-1AppendixA ReferenceThis appendix provides information about warranty and customer service, what information is required

Strany 76

A-2 ConnecT 56K DSU User ManualTelephone company informationThe following information may be required when applying to your local telephone company f

Strany 77 - A Reference

AT commandsConnecT 56K DSU User Manual A-3AT commandsThe following table lists the AT commands supported by the ConnecT 56K DSU. Table A-2 AT Comman

Strany 78 - Telephone company information

List of Figures vi ConnecT 56K DSU User Manual

Strany 79 - AT commands

A-4 ConnecT 56K DSU User ManualAT&V View current configuration noneAT&Wn Store user profile 0AT&Xn Transmit clock 0AT&Yn Power up use

Strany 80

AT commandsConnecT 56K DSU User Manual A-5AT_Tn Select test pattern 0AT_Xn Clock source select 0AT_Yn Secondary channel rate select 0AT CommandsComma

Strany 81

A-6 ConnecT 56K DSU User ManualConfiguration profilesThe following table lists the configuration profiles you can load using the Manual Command optio

Strany 82 - Configuration profiles

Configuration profilesConnecT 56K DSU User Manual A-7DTR command timeout (X100)30 30 30 30CD option NRML NRML NRML NRMLSR option NRML NRML NRML NRMLR

Strany 83

A-8 ConnecT 56K DSU User ManualFiguresThis section lists the figures referred to throughout the manual.Figure A-1 DTE and Loop Test DiagramDTE Trans

Strany 84

FiguresConnecT 56K DSU User Manual A-9Figure A-2 Loop Only Test DiagramFigure A-3 DTE Only Test DiagramDTE Transmit DTE Receive DTE TDDTE RDLoop On

Strany 85

A-10 ConnecT 56K DSU User ManualFigure A-4 DTE With Test Pattern DiagramFigure A-5 Test Pattern Only DiagramDTE Transmit DTE Receive DTE TDDTE RDDT

Strany 86

FiguresConnecT 56K DSU User Manual A-11Figure A-6 DSU to Modem Interconnect Diagram Figure A-7 EIA 232 Connector for 56 KB/s and 64 KB/s Applicatio

Strany 87

A-12 ConnecT 56K DSU User Manual

Strany 88

List of TablesConnecT 56K DSU User Manual viiTable 1-1 LED Identification ..................