Operation 23
MAIN MENU ALARMS NETWORK: OK
LOSS, 5
OOSS, 5
BPVS, 0
FR NET
‡
: OK, LOCAL, SOS, DLCI
RESET TIMER: 000 – 900, 30
§
RESET ALARMS?
PERFORMANCE NET PERFORMANCE RCV LVL: 0.0 dB, 7.3 dB, 13.6 dB, 19.7 dB, 26.0 dB,
32.3 dB, 38.4 dB, 44.4 dB, 50.5 dB
LOSS
OOSS
BPVS
CLEAR HISTORY?
FR PERFORMANCE LMI TYPE: ORIG, ANSI D, ITU A
PCKT SRC: UNI, NI
DLCI TOTAL: 000–999
†
DLCI Screen
CLEAR DLCI? TEST DLCI xxx?
‡
MAINTENANCE LOOP: NONE?, ENABLE LLB?, ENABLE DLB?, ENABLE LCL
ENABLE V54?, ENABLE RMT V54?, ENABLE RMT DLB
BERT: NONE,
EN. NET BERT? TP: MARKS, SPACES, 511, 2047
EN. DTE BERT? INJECT ERROR?
ERR CNT = 00000–65356
CLEAR ERR CNT?
DTE CONFIG RATE: 56 Kbps, 64 Kbps
1
DTE CLOCK: NOR, INV
TXCC CLOCK: EN, DIS
DTE DATA: NOR, INV
CTS: NORMAL, FORCED ON
CTS DELAY: 000–255
DCD: NORMAL, FORCED ON
DSR: NORMAL, FORCED ON
DTR: NORMAL, IGNORED
FRAME RLY CONFIG LMI MODE: OFF, ON, MON
‡
UNIT ID: 000 – 999
N391: 001–255, 006
N392: 01–10, 03
N393: 01–10, 04
T391: 05–30, 10
PVC MODE: DIS, EN
SOS TX: EN, DIS
‡
SOS RX: EN, DIS
‡
UTILITIES VERSION: z.zz
RESTORE FACTORY?
SET PASSWORD
*
:
Figure 4.2
DDS CSU/DSU Menutree
The three-digit current and threshold values (###/###)
range from 000 to 900. An asterisk (*) to the left of these
values indicates that the current value has exceeded the
threshold value. Pressing SELECT on a displayed alarm
allows editing the threshold parameters for that alarm.
The values are shown as (sss/ttttt). The 15-
minute current value (sss) ranges from 000
to 900. The 24-hour total values (ttttt) range
from 00000 to 65535.
† (Install mode only) If the DLCI TOTAL is greater than
000, a screen with the following format appears when
SELECT is pressed:
uuuu -> vvvv:www
xxxxms yyyykbps
uuuu - the local DLCI number
vvvv - ACT., IDLE, NEW, DEL., or REMOTE DLCI (if
discovered)
www - remote unit ID
xxxx - average delay (if discovered)
yyyy - committed information rate
*
This field establishes the unit password used for entering
the front panel interface. A password must be eight
characters. SCROLL increments the characters (0–9, A–
Z, a–z). The cursor blinks over the character or digit to be
selected or modified. SELECT accepts the current value
and moves the cursor right. When the eighth character is
selected, a verification screen appears. Reenter the
password.
‡ Monitor option only
§
This does not apply to frame relay alarms.
Default values are shown in bold.
1
The network configuration is automatically set when the
DTE Rate is set. For example, 56 Kbps DTE Rate sets the
network to DDS I and 64 Kbps DTE Rate sets the network
to DDS II CC 64K.