Configuration 3-5PRISM 4151
A
LARM
C
ONFIGURATION
The Alarm Configuration screen (Figure 3-12) allows you
to review and set alarm related thresholds for the selected
element. These thresholds are the minimum acceptable per-
formance levels. To modify the parameters, highlight the
desired statistic and press the spacebar to increase the value
or backspace to decrease the value and press <return>. If
this value is later surpassed, an alarm indication will appear.
A field set to none (
--
) will cause the element not to alarm
on that statistic.
Loss of Signal Seconds
: A one second period in which the
DDS received signal is interrupted. Options are 1, 2, 3, 4, 5
,
10, 20, 30, and none (--).
Out of Service Seconds:
A one second period during which
the Out Of Service code is received. Options are 1, 2, 3, 4, 5,
10, 20, 30, and none (--)
.
Out of Frame Seconds
: A one second period in which the
Out Of Frame code is received or a frame sync loss
occurred. Options are 1, 2, 3, 4, 5, 10, 20, 30, and none
(--).
Alarm Reset Timer
: Determines the number of seconds
after alarm conditions clear before indications are removed.
Options are 10, 30
, 60, 90, 100, 200, 300, 400, 500, 600,
700, 800, 900, and None. If this value is set to None, the
alarm conditions will not automatically reset.
Figure 3-12 Alarm Configuration Screen