
6 C
HAPTER
2: I
NSTALLATION
AND
C
ONFIGURATION
Wallmount
Installation
Using Adhesive Strips
1 Select a place close to an AC outlet with clearance for the signal
and power cables. The indicators and switches should be easily
accessible.
2 Verify the mounting surface is clean.
3 Cut the adhesive strip to the desired length and affix the backing
of one piece to the underside of the unit.
4 Attach the other adhesive strip to the piece on the underside of
the unit.
5 Remove the backing to expose the sticky surface.
6 Press the underside of the unit firmly against the selected place.
Using Screws
1 Select a place close to an AC outlet with clearance for the signal
and power cables. The indicators and switches should be easily
accessible.
2 Vertically place two #6 screws 3-13⁄32 inches apart at the
selected place. Leave the screws out about an eighth of an inch.
3 Place the upright unit over the screws until the holes engage and
slide the unit down until it locks.
Connections
The S Lite has female DB-25 connectors for the DCE and DTE
interfaces, and a power connector. The following paragraphs
describe these connections.
DCE and DTE
Connections
Table 2-1 shows the pinout for the DCE and DTE connectors.
Table 2-1 DCE and DTE Connector Pinout
Pin DCE and DTE Pin DCE and DTE
1 Shield Ground 14 TXD B
2 TXD A 15 TXC A
3 RXD A 16 RXD B
4RTS A 17 RXC A
5CTS A 18 LL
6DSR A 19 RTS B
7 Signal Ground 20 DTR A
8DCD A 21 RL
9RXC B 22 DSR B
10 DCD B 23 DTR B
11 SCTE B 24 SCTE A
12 TXC B 25 TM
13 CTS B
Komentáře k této Příručce