1-12 WANsuite 5160/5130
CAUTION: FCC rules require that interconnecting cables carrying high-speed
data be shielded appropriately in order to minimize radio frequency
interference.
Network Interfaces
Labeled on the rear panel of the WANsuite 5160 as NET #1 and NET #2, and
on the 5130 as NET, these interfaces’ connections are standard RJ-48C,
eight-pin modular jacks that contain an automatic line build out (ALBO). The
ALBO allows the unit to be located a substantial distance away from the telco
network interface with a receive signal level to −27 dB. These interfaces
operate in either long-haul or short-haul mode. To view the pinout
assignments for these interfaces, refer to Network 1 (5160) or Network (5130)
Interface Pin Assignments and Network 2 (5160 Only) Interface Pin
Assignments on page A-10.
The Network interface transmit LBO level should be set as instructed in the
Line Build-out parameters section on page 3-7. Maximum suggested cable
lengths for the connection from the unit to the network are listed in the table
below. Calculations are based on a cable temperature of 70 °F, 0.083 µF/mile
capacitance, a 27-dB loss, and a 100-Ω, non-loaded, twisted-pair cable.
CAUTION: In accordance with FCC Rules, Part 68.218(b), you must notify the
telephone company prior to disconnecting this product.
Power Connection
The POWER port is an eight-pin circular mini-DIN connector that connects
either an autoranging 100–240 VAC (shown in Figure 1.5 below) or an
autoranging 18−150 VDC external power supply (connection shown in Figure
1.6 below) to the unit. The WANsuite 5160/5130 must be used with the UL
Listed/CSA Certified Class 2 power supply provided with the unit or ordered
separately from Verilink. The unit has no power switch.
Cable Type
Loss per 1000 ft
(dB)
Max Cable Length
(ft)
26-gauge PIC 6.8 4,400
24-gauge PIC 5.4 5,500
22-gauge PIC 4.2 7,100
19-gauge PIC 3.0 10,000
(PIC - Plastic Insulated Cable)
Komentáře k této Příručce