DIDCSU E1 Version
Verilink DIDCSU 2912 User Manual
4-5
Administration Menu
Use the
Controller Administration Menu (Administration Menu)
to modify and manage system-wide parameters, such as changing
time or passwords.
To access these parameters, from the
Main Menu
, first select the
DIDCSU shelf/slot position, then enter the letter “O” to access the
Administration Menu
.
Figure 4-3 Administration Menu
Table 4-3 Administration Menu Parameters
Command Description Options
O Switch Over Permanent—Use this option to designate partition A or B
and its corresponding firmware version to be loaded when power is
applied to the module. Before choosing a partition, ensure that a
firmware version exists on that partition by using the Query Firmware
option below.
1) A
2) B
Q Query Firmware—Use this option to display the firmware versions and
their status for the A and B flashbanks. A noticeable delay occurs as
the flash bank versions are read.
R Reset Card—Use this option to re-initialize the DIDCSU. Code is not
copied from either partition. Instead, the counters are all rest to zero.
Do not use Reset Card to test newly downloaded firmware, use
Switchover Once instead.
Confirmation is
required.
Y Switchover Once—Use this option for testing new firmware versions.
This option switches the module from partition A to B or vice versa.
The partition selected is not set as the default power-up partition.
1) A
2) B
-- NCM CONTROLLER ADMINISTRATION MENU --
-- NCM CONTROLLER ADMINISTRATION MENU ---- NCM CONTROLLER ADMINISTRATION MENU --
-- NCM CONTROLLER ADMINISTRATION MENU --
Date/Time/Zone: 05-21-99 10:26:57 PST DTS ON
Date/Time/Zone: 05-21-99 10:26:57 PST DTS ONDate/Time/Zone: 05-21-99 10:26:57 PST DTS ON
Date/Time/Zone: 05-21-99 10:26:57 PST DTS ON
Node Address: [0.0.0.204]
Node Address: [0.0.0.204]Node Address: [0.0.0.204]
Node Address: [0.0.0.204]
Node ID: 204
Node ID: 204Node ID: 204
Node ID: 204
Site Name: Tech Pubs & Trainin
Site Name: Tech Pubs & TraininSite Name: Tech Pubs & Trainin
Site Name: Tech Pubs & Trainin
System Uptime: 26:26:04
System Uptime: 26:26:04System Uptime: 26:26:04
System Uptime: 26:26:04
--- DIDCSU 2912 -- Card Administration -- [01,02] ---
--- DIDCSU 2912 -- Card Administration -- [01,02] --- --- DIDCSU 2912 -- Card Administration -- [01,02] ---
--- DIDCSU 2912 -- Card Administration -- [01,02] ---
O) switch over permanent
O) switch over permanentO) switch over permanent
O) switch over permanent
Q) query firmware
Q) query firmwareQ) query firmware
Q) query firmware
R) reset card
R) reset cardR) reset card
R) reset card
Y) switch over once
Y) switch over onceY) switch over once
Y) switch over once
I) change site name
I) change site nameI) change site name
I) change site name
U) clear card configuration
U) clear card configurationU) clear card configuration
U) clear card configuration
F) flash copy (B => A) [for version 2.27 and later only]
F) flash copy (B => A) [for version 2.27 and later only]F) flash copy (B => A) [for version 2.27 and later only]
F) flash copy (B => A) [for version 2.27 and later only]
X) exit this screen
X) exit this screenX) exit this screen
X) exit this screen
A [0.0.0.204] [1,2] DIDCSU 2912 >
A [0.0.0.204] [1,2] DIDCSU 2912 >A [0.0.0.204] [1,2] DIDCSU 2912 >
A [0.0.0.204] [1,2] DIDCSU 2912 >
Komentáře k této Příručce